Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Simulation of medical ultrasound ima...
~
Imani, Farzin.
Linked to FindBook
Google Book
Amazon
博客來
Simulation of medical ultrasound images using linear systems theory.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Simulation of medical ultrasound images using linear systems theory./
Author:
Imani, Farzin.
Description:
54 p.
Notes:
Source: Dissertation Abstracts International, Volume: 64-03, Section: B, page: 1357.
Contained By:
Dissertation Abstracts International64-03B.
Subject:
Engineering, Biomedical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3086279
Simulation of medical ultrasound images using linear systems theory.
Imani, Farzin.
Simulation of medical ultrasound images using linear systems theory.
- 54 p.
Source: Dissertation Abstracts International, Volume: 64-03, Section: B, page: 1357.
Thesis (Ph.D.)--University of Colorado Health Sciences Center, 2003.
Medical Ultrasonography provides an accurate real-time assessment of organs and systems without exposing the patient to harmful ionizing radiation. These features and the cost effectiveness of the procedure have made ultrasonography one of the most widely used diagnostic medical imaging modalities. The practice of ultrasound is expanding into diverse areas of clinical medicine, and as a result, there is an increasing demand for education and training in the use of ultrasound.Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Simulation of medical ultrasound images using linear systems theory.
LDR
:03309nmm 2200313 4500
001
1857549
005
20040816072813.5
008
130614s2003 eng d
035
$a
(UnM)AAI3086279
035
$a
AAI3086279
040
$a
UnM
$c
UnM
100
1
$a
Imani, Farzin.
$3
1945265
245
1 0
$a
Simulation of medical ultrasound images using linear systems theory.
300
$a
54 p.
500
$a
Source: Dissertation Abstracts International, Volume: 64-03, Section: B, page: 1357.
500
$a
Director: Imran Shah.
502
$a
Thesis (Ph.D.)--University of Colorado Health Sciences Center, 2003.
520
$a
Medical Ultrasonography provides an accurate real-time assessment of organs and systems without exposing the patient to harmful ionizing radiation. These features and the cost effectiveness of the procedure have made ultrasonography one of the most widely used diagnostic medical imaging modalities. The practice of ultrasound is expanding into diverse areas of clinical medicine, and as a result, there is an increasing demand for education and training in the use of ultrasound.
520
$a
This project addresses a novel ultrasonographic simulation algorithm that has the ability to generate ultrasonograms from any position and orientation, from either the surface of or inside a virtual body. The algorithm is able to take as inputs the spatial location and ultrasound characteristics of the tissues and in turn produces images similar to true ultrasonograms with a frame rate comparable to real medical ultrasound instruments.
520
$a
Initially, the trainee determines the location and orientation of the virtual transducer. From the obtained information, the simulator retrieves the necessary anatomic data from a segmented Visible Human dataset to localize the organs and tissues in the image plane. Then, just like real instruments, the ultrasound beams are emitted from the virtual transducer. Waves reflected from interfaces and speckle noise from subwavelength scatterers are calculated based on the linear systems theory, tissue properties, and the physics of ultrasound. In the case of high amplitude reflections, the simulator also processes the reverberations. The results pass through filters for time gain compensation and motion blur. After correcting for brightness and contrast, the image is displayed on a screen as the ultrasonogram of the volume under investigation. The simulator also labels the various structures in order to clarify the images under examination.
520
$a
Statistical analyses of the images confirmed the similarity between the simulated and the real ultrasonograms. Frequency domain analyses also demonstrated identical frequency patterns between the simulated and real images. Each frame took 186.8 milliseconds on average to generate on a 2.0 GHz Pentium 4 system with 1 GB random access memory, which is comparable to real ultrasound instruments.
520
$a
This study demonstrates the feasibility of creating simulated ultrasonograms for interactive training and education.
590
$a
School code: 0831.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Health Sciences, Radiology.
$3
1019076
690
$a
0541
690
$a
0574
710
2 0
$a
University of Colorado Health Sciences Center.
$3
1023815
773
0
$t
Dissertation Abstracts International
$g
64-03B.
790
1 0
$a
Shah, Imran,
$e
advisor
790
$a
0831
791
$a
Ph.D.
792
$a
2003
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3086279
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9176249
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login