Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
The development and application of g...
~
Chen, Ting.
Linked to FindBook
Google Book
Amazon
博客來
The development and application of glucose electrodes based on "wired" glucose oxidase.
Record Type:
Electronic resources : Monograph/item
Title/Author:
The development and application of glucose electrodes based on "wired" glucose oxidase./
Author:
Chen, Ting.
Description:
147 p.
Notes:
Source: Dissertation Abstracts International, Volume: 62-12, Section: B, page: 5688.
Contained By:
Dissertation Abstracts International62-12B.
Subject:
Chemistry, Analytical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3036168
ISBN:
0493491899
The development and application of glucose electrodes based on "wired" glucose oxidase.
Chen, Ting.
The development and application of glucose electrodes based on "wired" glucose oxidase.
- 147 p.
Source: Dissertation Abstracts International, Volume: 62-12, Section: B, page: 5688.
Thesis (Ph.D.)--The University of Texas at Austin, 2001.
The sensitivity of rapidly responding “wired” glucose sensing microelectrodes with a tailored outer membrane was examined <italic>in vivo </italic>. It is shown that these microsensors maintained <italic>in vivo </italic> sensitivities similar to those in buffer before the implantation and after the explantation when implanted intravenously or intraperitoneally for several hours in the rat. Maintenance of the sensitivity <italic>in vivo </italic> provides the basis for pre-calibrating the microsensors <italic> in vitro</italic>, lifting the requirement of <italic>in vivo</italic> calibration. The <italic>in vitro</italic> calibration results can be used by the patients as a reference in judging the reliability of sensor readings.
ISBN: 0493491899Subjects--Topical Terms:
586156
Chemistry, Analytical.
The development and application of glucose electrodes based on "wired" glucose oxidase.
LDR
:03852nmm 2200313 4500
001
1855148
005
20040624070200.5
008
130614s2001 eng d
020
$a
0493491899
035
$a
(UnM)AAI3036168
035
$a
AAI3036168
040
$a
UnM
$c
UnM
100
1
$a
Chen, Ting.
$3
1287144
245
1 0
$a
The development and application of glucose electrodes based on "wired" glucose oxidase.
300
$a
147 p.
500
$a
Source: Dissertation Abstracts International, Volume: 62-12, Section: B, page: 5688.
500
$a
Supervisor: Adam Heller.
502
$a
Thesis (Ph.D.)--The University of Texas at Austin, 2001.
520
$a
The sensitivity of rapidly responding “wired” glucose sensing microelectrodes with a tailored outer membrane was examined <italic>in vivo </italic>. It is shown that these microsensors maintained <italic>in vivo </italic> sensitivities similar to those in buffer before the implantation and after the explantation when implanted intravenously or intraperitoneally for several hours in the rat. Maintenance of the sensitivity <italic>in vivo </italic> provides the basis for pre-calibrating the microsensors <italic> in vitro</italic>, lifting the requirement of <italic>in vivo</italic> calibration. The <italic>in vitro</italic> calibration results can be used by the patients as a reference in judging the reliability of sensor readings.
520
$a
The causes of much more rapid decaying current in the “wired” glucose oxidase-based microelectrodes in serum compared to their sensitivity in buffer were studied. Urate and transition metal ions were identified as two main causes for the loss in current. Urate is electrooxidized to dimeric or trimeric products, which precipitate in the electrocatalytic film, reducing the mobility of the redox sites of the polymer. Transition metal ions coordinatively crosslink pyridine or imidazole functions of the redox polymers and also inhibit glucose oxidase.
520
$a
Implantable “wired” glucose microsensors with novel polyionic membrane for mass transport-controlling were developed and tested in the jugular veins and in the intrascapular subcutaneous region of non-diabetic Sprague-Dawley rats. The micromembranes were assembled by sequentially chemisorbing polyanions and polycations on miniature enzyme electrodes. The sequential chemisorption process allowed the simultaneous tailoring of their sensitivity, dynamic range, drift and selectivity. The membranes also retained transition metal ions that bound to and damaged the redox polymer “wiring” the enzyme. All of the <italic>in vivo</italic> data points measured by the microsensors were clinically accurate after correcting the lag time of the glycemia in the subcutaneous fluid behind that of blood withdrawn from the vein.
520
$a
The “wired” glucose enzyme microelectrode was also used as the microanode in developing a compartmentless miniature biofuel cell intended to be an implanted mini power source for medical microdevice. The glucose-oxidizing anode was combined with a high current output “wired” laccase microcathode, which catalyzes the electro-reduction of O<sub>2</sub> to water. The areas of the anode and the cathode of the cell are much smaller than any previously reported fuel cell. The power density of the cell exceeds by a factor of five that of the highest power density of earlier reported glucose-air biofuel cells. The effects of different buffers, oxygen concentration, pH and chloride on cell current were investigated.
590
$a
School code: 0227.
650
4
$a
Chemistry, Analytical.
$3
586156
650
4
$a
Chemistry, Biochemistry.
$3
1017722
690
$a
0486
690
$a
0487
710
2 0
$a
The University of Texas at Austin.
$3
718984
773
0
$t
Dissertation Abstracts International
$g
62-12B.
790
1 0
$a
Heller, Adam,
$e
advisor
790
$a
0227
791
$a
Ph.D.
792
$a
2001
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3036168
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9173848
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login