Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Detection of indoor airborne fungal ...
~
Perez, Hernando R.
Linked to FindBook
Google Book
Amazon
博客來
Detection of indoor airborne fungal contamination through examination of building heating, ventilating and air conditioning (HVAC) filters.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Detection of indoor airborne fungal contamination through examination of building heating, ventilating and air conditioning (HVAC) filters./
Author:
Perez, Hernando R.
Description:
146 p.
Notes:
Source: Dissertation Abstracts International, Volume: 65-11, Section: B, page: 5642.
Contained By:
Dissertation Abstracts International65-11B.
Subject:
Health Sciences, Occupational Health and Safety. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3154713
ISBN:
0496152750
Detection of indoor airborne fungal contamination through examination of building heating, ventilating and air conditioning (HVAC) filters.
Perez, Hernando R.
Detection of indoor airborne fungal contamination through examination of building heating, ventilating and air conditioning (HVAC) filters.
- 146 p.
Source: Dissertation Abstracts International, Volume: 65-11, Section: B, page: 5642.
Thesis (Ph.D.)--Purdue University, 2004.
This three phase research involved the pilot testing, laboratory development and field evaluation of a method for the quantification of viable fungal particles on heating, ventilating and air conditioning (HVAC) system filters. The primary purpose of this three phase work was to evaluate whether or not the airborne concentration of viable fungal particles calculated through the quantification of building HVAC filters is significantly associated with the average airborne viable fungal concentration as calculated through the collection of multiple single stage viable impactor samples taken at regular intervals while filters are in service. A second purpose of this research was to evaluate whether not the filter quantification method is able to differentiate, with respect to viable fungal airborne levels, between areas suspected of having significantly different concentrations.{09}The filter quantification method involved the immersion of filter samples in 0.9% sterile saline, the shaking of the filter/saline combination, and the plating of aliquots of the shaking solution onto solid growth media. The inoculated media plates were incubated at room temperature for 96 hours at which time colonies were counted. The initial pilot phase of this research involved a comparison between complaint and non-complaint university building HVAC filters. The results of the comparison indicated a statistically significant greater number of mold spores on the complaint filters than on the non-complaint filters when the results were normalized for airflow. The second research phase involved the use of a ventilation test chamber in which test filters were loaded with aerosolized A. niger or P. chrysogenum fungal spore suspensions before being processed as described above. Fungal recovery values as high as 93% were found with this method. In some cases recovery values of greater than 100% were obtained. The third phase of this research involved the comparison of filter quantification and single stage impactor results in several buildings. A statistically significant relationship between the two sampling procedures was found at both shorter and longer term sampling periods. Also in this phase, the filter quantification method was found to be more likely than impactor sampling to differentiate between areas with respect to airborne fungal concentrations.
ISBN: 0496152750Subjects--Topical Terms:
1017799
Health Sciences, Occupational Health and Safety.
Detection of indoor airborne fungal contamination through examination of building heating, ventilating and air conditioning (HVAC) filters.
LDR
:03327nmm 2200277 4500
001
1852208
005
20051230065437.5
008
130614s2004 eng d
020
$a
0496152750
035
$a
(UnM)AAI3154713
035
$a
AAI3154713
040
$a
UnM
$c
UnM
100
1
$a
Perez, Hernando R.
$3
1940074
245
1 0
$a
Detection of indoor airborne fungal contamination through examination of building heating, ventilating and air conditioning (HVAC) filters.
300
$a
146 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-11, Section: B, page: 5642.
500
$a
Major Professor: Neil J. Zimmerman.
502
$a
Thesis (Ph.D.)--Purdue University, 2004.
520
$a
This three phase research involved the pilot testing, laboratory development and field evaluation of a method for the quantification of viable fungal particles on heating, ventilating and air conditioning (HVAC) system filters. The primary purpose of this three phase work was to evaluate whether or not the airborne concentration of viable fungal particles calculated through the quantification of building HVAC filters is significantly associated with the average airborne viable fungal concentration as calculated through the collection of multiple single stage viable impactor samples taken at regular intervals while filters are in service. A second purpose of this research was to evaluate whether not the filter quantification method is able to differentiate, with respect to viable fungal airborne levels, between areas suspected of having significantly different concentrations.{09}The filter quantification method involved the immersion of filter samples in 0.9% sterile saline, the shaking of the filter/saline combination, and the plating of aliquots of the shaking solution onto solid growth media. The inoculated media plates were incubated at room temperature for 96 hours at which time colonies were counted. The initial pilot phase of this research involved a comparison between complaint and non-complaint university building HVAC filters. The results of the comparison indicated a statistically significant greater number of mold spores on the complaint filters than on the non-complaint filters when the results were normalized for airflow. The second research phase involved the use of a ventilation test chamber in which test filters were loaded with aerosolized A. niger or P. chrysogenum fungal spore suspensions before being processed as described above. Fungal recovery values as high as 93% were found with this method. In some cases recovery values of greater than 100% were obtained. The third phase of this research involved the comparison of filter quantification and single stage impactor results in several buildings. A statistically significant relationship between the two sampling procedures was found at both shorter and longer term sampling periods. Also in this phase, the filter quantification method was found to be more likely than impactor sampling to differentiate between areas with respect to airborne fungal concentrations.
590
$a
School code: 0183.
650
4
$a
Health Sciences, Occupational Health and Safety.
$3
1017799
650
4
$a
Health Sciences, Public Health.
$3
1017659
690
$a
0354
690
$a
0573
710
2 0
$a
Purdue University.
$3
1017663
773
0
$t
Dissertation Abstracts International
$g
65-11B.
790
1 0
$a
Zimmerman, Neil J.,
$e
advisor
790
$a
0183
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3154713
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9201722
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login