Liquid-phase cavity ring-down spectroscopy and its application as a chromatographic detector.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Liquid-phase cavity ring-down spectroscopy and its application as a chromatographic detector./
Author:
Bechtel, Kate L.
Description:
122 p.
Notes:
Source: Dissertation Abstracts International, Volume: 65-09, Section: B, page: 4543.
Contained By:
Dissertation Abstracts International65-09B.
Subject:
Chemistry, Analytical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3145465
ISBN:
0496043684
Liquid-phase cavity ring-down spectroscopy and its application as a chromatographic detector.
Bechtel, Kate L.
Liquid-phase cavity ring-down spectroscopy and its application as a chromatographic detector.
- 122 p.
Source: Dissertation Abstracts International, Volume: 65-09, Section: B, page: 4543.
Thesis (Ph.D.)--Stanford University, 2004.
A new liquid-phase absorption detector is developed that demonstrates a minimum detectable absorbance of 10-8 absorbance units (AU). This value is more than 40 times lower than commercially available UV-Vis detectors. This new detector is a result of the extension of cavity ring-down spectroscopy (CRDS), a primarily gas-phase technique, to the liquid phase.
ISBN: 0496043684Subjects--Topical Terms:
586156
Chemistry, Analytical.
Liquid-phase cavity ring-down spectroscopy and its application as a chromatographic detector.
LDR
:02997nmm 2200313 4500
001
1844640
005
20051017073530.5
008
130614s2004 eng d
020
$a
0496043684
035
$a
(UnM)AAI3145465
035
$a
AAI3145465
040
$a
UnM
$c
UnM
100
1
$a
Bechtel, Kate L.
$3
1932829
245
1 0
$a
Liquid-phase cavity ring-down spectroscopy and its application as a chromatographic detector.
300
$a
122 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-09, Section: B, page: 4543.
500
$a
Adviser: Richard N. Zare.
502
$a
Thesis (Ph.D.)--Stanford University, 2004.
520
$a
A new liquid-phase absorption detector is developed that demonstrates a minimum detectable absorbance of 10-8 absorbance units (AU). This value is more than 40 times lower than commercially available UV-Vis detectors. This new detector is a result of the extension of cavity ring-down spectroscopy (CRDS), a primarily gas-phase technique, to the liquid phase.
520
$a
Liquid-phase CRDS is accomplished by incorporating a specially designed flow cell into the ring-down cavity. The flow cell minimizes optical losses by allowing p-polarized light to refract through the cell interfaces at Brewster's angle. This flow cell has been coupled to the output of an HPLC separation, enabling the detection of analytes by CRDS.
520
$a
This technique was initially demonstrated by the separation and detection of a series of anthraquinones using a pulsed laser source at 470 nm. Ring-down time constants with the Brewster's angle flow cell, having an interior optical pathlength of 0.3 mm, were up to 2.5 mus in a 1-m cavity. The baseline noise level (rms) of this system was 3.2 x 10-6 AU, rivaling the best commercial UV-Vis detector, which exhibits a baseline noise of 3.0 x 10-6 AU. The CRDS detector performance, while notable, was limited in this case because of the nature of the light source: excitation of multiple cavity modes resulted in a 1% shot-to-shot variation in the ring-down time constant.
520
$a
The detection limit of the liquid-phase CRDS detector was improved through the use of a single-mode continuous-wave (cw) laser source at 488 nm. Its narrow linewidth enabled excitation of a single cavity mode, resulting in shot-to-shot variations in the ring-down time constant as low as 0.04%. Furthermore, through improved cell characterization, ring-down time constants with the same flow cell and cavity length were nearly 6 mus. The baseline noise (rms) for this system during an HPLC separation of the same analytes was 6.7 x 10-8 AU. These results clearly illustrate the value of liquid-phase CRDS and its use as an absorption detector for HPLC measurements.
590
$a
School code: 0212.
650
4
$a
Chemistry, Analytical.
$3
586156
650
4
$a
Physics, Optics.
$3
1018756
690
$a
0486
690
$a
0752
710
2 0
$a
Stanford University.
$3
754827
773
0
$t
Dissertation Abstracts International
$g
65-09B.
790
1 0
$a
Zare, Richard N.,
$e
advisor
790
$a
0212
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3145465
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9194154
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login