Fourier transform infrared spectroscopic measurement of carbon monoxide and nitric oxide in sidestream cigarette smoke in real time using a hollow waveguide gas cell and non-imaging optics.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Fourier transform infrared spectroscopic measurement of carbon monoxide and nitric oxide in sidestream cigarette smoke in real time using a hollow waveguide gas cell and non-imaging optics./
作者:
Thompson, Bruce T.
面頁冊數:
236 p.
附註:
Source: Dissertation Abstracts International, Volume: 65-07, Section: B, page: 3441.
Contained By:
Dissertation Abstracts International65-07B.
標題:
Chemistry, Analytical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3140771
ISBN:
0496879119
Fourier transform infrared spectroscopic measurement of carbon monoxide and nitric oxide in sidestream cigarette smoke in real time using a hollow waveguide gas cell and non-imaging optics.
Thompson, Bruce T.
Fourier transform infrared spectroscopic measurement of carbon monoxide and nitric oxide in sidestream cigarette smoke in real time using a hollow waveguide gas cell and non-imaging optics.
- 236 p.
Source: Dissertation Abstracts International, Volume: 65-07, Section: B, page: 3441.
Thesis (Ph.D.)--Georgia Institute of Technology, 2004.
The application of a hollow waveguide (HW) was investigated as a gas cell for analytical infrared analysis. The analysis was the measurement of carbon monoxide (CO) and nitric oxide (NO) in sidestream cigarette smoke. An FT-IR analysis system was setup with a 3m multi-pass gas cell and a 55cm by 2mm i.d. Ag/AgI coated HW in tandem with individual CO and NO gas analyzers. The HW demonstrated response times an order of magnitude less than the larger volume multi-pass gas cell and slightly faster than the single analyte gas analyzer. Furthermore, it has been demonstrated that the HW provides up to approx. 60% greater sensitivity on a per meter optical path basis than the multi-pass gas cell of the analytes investigated due to increased optical efficiency maximizing the light concentration within the gaseous sample volume. Simulations in 3D showed the sensitivity could theoretically improve by more than an order of magnitude if the IR beam was coupled more efficiently into the waveguide. Both FT-IR configurations gave statistically equivalent results for CO to the independent analyzers. With the HW increased temporal resolution, inter-puff measurements comparable to the gas analyzer were achieved at a lower spectral resolution.
ISBN: 0496879119Subjects--Topical Terms:
586156
Chemistry, Analytical.
Fourier transform infrared spectroscopic measurement of carbon monoxide and nitric oxide in sidestream cigarette smoke in real time using a hollow waveguide gas cell and non-imaging optics.
LDR
:03196nmm 2200277 4500
001
1840376
005
20050721103003.5
008
130614s2004 eng d
020
$a
0496879119
035
$a
(UnM)AAI3140771
035
$a
AAI3140771
040
$a
UnM
$c
UnM
100
1
$a
Thompson, Bruce T.
$3
1928717
245
1 0
$a
Fourier transform infrared spectroscopic measurement of carbon monoxide and nitric oxide in sidestream cigarette smoke in real time using a hollow waveguide gas cell and non-imaging optics.
300
$a
236 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-07, Section: B, page: 3441.
500
$a
Director: Boris Mizaikoff.
502
$a
Thesis (Ph.D.)--Georgia Institute of Technology, 2004.
520
$a
The application of a hollow waveguide (HW) was investigated as a gas cell for analytical infrared analysis. The analysis was the measurement of carbon monoxide (CO) and nitric oxide (NO) in sidestream cigarette smoke. An FT-IR analysis system was setup with a 3m multi-pass gas cell and a 55cm by 2mm i.d. Ag/AgI coated HW in tandem with individual CO and NO gas analyzers. The HW demonstrated response times an order of magnitude less than the larger volume multi-pass gas cell and slightly faster than the single analyte gas analyzer. Furthermore, it has been demonstrated that the HW provides up to approx. 60% greater sensitivity on a per meter optical path basis than the multi-pass gas cell of the analytes investigated due to increased optical efficiency maximizing the light concentration within the gaseous sample volume. Simulations in 3D showed the sensitivity could theoretically improve by more than an order of magnitude if the IR beam was coupled more efficiently into the waveguide. Both FT-IR configurations gave statistically equivalent results for CO to the independent analyzers. With the HW increased temporal resolution, inter-puff measurements comparable to the gas analyzer were achieved at a lower spectral resolution.
520
$a
The HW optical configuration was modeled for ray tracing in MATLAB. Simulations in 2-D and 3-D were accomplished. The simulations show a major drawback to HW optimization is the coupling of the infrared beam into the waveguide. As demonstrated in a 3-D simulation, approximately 97% of the rays are rejected when an off-axis parabolic mirror with 25.4mm focal length is used to focus the IR beam into the 2mm i.d. waveguide. Repeating the simulation with longer focal length mirrors showed improved in IR coupling into the waveguide from 3% to 85%. Simulations applying a compound parabolic concentrator show comparable performance to the traditional design of two OAP mirrors to collect rays from the HW and focus onto the detector, but in a much smaller configuration. The simulation routines can be used to further improve the design of this and other optical sensing systems and enhanced by incorporating a spectral component to the simulation.
590
$a
School code: 0078.
650
4
$a
Chemistry, Analytical.
$3
586156
690
$a
0486
710
2 0
$a
Georgia Institute of Technology.
$3
696730
773
0
$t
Dissertation Abstracts International
$g
65-07B.
790
1 0
$a
Mizaikoff, Boris,
$e
advisor
790
$a
0078
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3140771
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9189890
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入