Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Microfabricated voltammetric neuro-a...
~
Strong, Timothy Delbert.
Linked to FindBook
Google Book
Amazon
博客來
Microfabricated voltammetric neuro-arrays for use in vitro.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Microfabricated voltammetric neuro-arrays for use in vitro./
Author:
Strong, Timothy Delbert.
Description:
137 p.
Notes:
Source: Dissertation Abstracts International, Volume: 65-06, Section: B, page: 3077.
Contained By:
Dissertation Abstracts International65-06B.
Subject:
Engineering, Electronics and Electrical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3137947
ISBN:
0496851176
Microfabricated voltammetric neuro-arrays for use in vitro.
Strong, Timothy Delbert.
Microfabricated voltammetric neuro-arrays for use in vitro.
- 137 p.
Source: Dissertation Abstracts International, Volume: 65-06, Section: B, page: 3077.
Thesis (Ph.D.)--University of Michigan, 2004.
This work describes the manufacture and testing of microfabricated voltammetric electrode arrays for the neuroelectrical and neurochemical study of neurons in cell culture. Neurochemical sensing of dopamine and its metabolites is provided by voltammetry. Two versions of the device are presented: a passive device containing only the chemical sensing array, and a prototype active device with on-board signal amplification. The passive device contains a four by four array of sixteen neurochemical/neuroelectrical sensors. Five versions of the passive device are presented with platinum working electrode areas of 10000, 1024, 64, 16, and 4mum2. The reference electrodes on the device are silver/silver chloride pseudo-reference electrodes with areas of 12544, 1444, 196 and 64mum2 respectively. The active devices have working electrode areas of 64mum2 and reference electrode areas of 196mum2. Fabrication processes for passive and active arrays are described. The active devices are created by performing post-processing on standard CMOS foundry fabricated die obtained through the MOSIS service.
ISBN: 0496851176Subjects--Topical Terms:
626636
Engineering, Electronics and Electrical.
Microfabricated voltammetric neuro-arrays for use in vitro.
LDR
:03235nmm 2200337 4500
001
1840373
005
20050721103003.5
008
130614s2004 eng d
020
$a
0496851176
035
$a
(UnM)AAI3137947
035
$a
AAI3137947
040
$a
UnM
$c
UnM
100
1
$a
Strong, Timothy Delbert.
$3
1928714
245
1 0
$a
Microfabricated voltammetric neuro-arrays for use in vitro.
300
$a
137 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-06, Section: B, page: 3077.
500
$a
Chair: Richard B. Brown.
502
$a
Thesis (Ph.D.)--University of Michigan, 2004.
520
$a
This work describes the manufacture and testing of microfabricated voltammetric electrode arrays for the neuroelectrical and neurochemical study of neurons in cell culture. Neurochemical sensing of dopamine and its metabolites is provided by voltammetry. Two versions of the device are presented: a passive device containing only the chemical sensing array, and a prototype active device with on-board signal amplification. The passive device contains a four by four array of sixteen neurochemical/neuroelectrical sensors. Five versions of the passive device are presented with platinum working electrode areas of 10000, 1024, 64, 16, and 4mum2. The reference electrodes on the device are silver/silver chloride pseudo-reference electrodes with areas of 12544, 1444, 196 and 64mum2 respectively. The active devices have working electrode areas of 64mum2 and reference electrode areas of 196mum2. Fabrication processes for passive and active arrays are described. The active devices are created by performing post-processing on standard CMOS foundry fabricated die obtained through the MOSIS service.
520
$a
Results from living human neuron cultures plated onto the passive devices are presented. The neurons survived and produced data throughout a study period of seventy-five days. Calibration curves for dopamine taken in buffer solution with commercial equipment show a detection limit of 662nM with a sensitivity of 224nA/M on the 64mum2 working electrode devices. Calibration data taken in culture media with equipment optimized for the sensors suggests detection limits for dopamine below 100nM.
520
$a
A technique for creating miniature silver/silver chloride reference electrodes in standard reactive-ion etch equipment is also presented. The process is characterized for the effect of the process parameters on the estimated lifetime of the devices soaking in phosphate buffer solution. A device using the optimized set of parameters should last approximately 35 days in phosphate buffer solution.
520
$a
The passive devices appear to be very effective neuroscience tools. The data collected from the human neuron culture suggests the ability to study not only the electrical communication among the cultured neurons, but also allow examination of corresponding neurotransmitter releases.
590
$a
School code: 0127.
650
4
$a
Engineering, Electronics and Electrical.
$3
626636
650
4
$a
Biology, Neuroscience.
$3
1017680
650
4
$a
Chemistry, Analytical.
$3
586156
650
4
$a
Engineering, Biomedical.
$3
1017684
690
$a
0544
690
$a
0317
690
$a
0486
690
$a
0541
710
2 0
$a
University of Michigan.
$3
777416
773
0
$t
Dissertation Abstracts International
$g
65-06B.
790
1 0
$a
Brown, Richard B.,
$e
advisor
790
$a
0127
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3137947
based on 0 review(s)
Location:
全部
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9189887
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login