Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Passive cooling strategies for build...
~
La Roche, Pablo Miguel.
Linked to FindBook
Google Book
Amazon
博客來
Passive cooling strategies for buildings in hot climates with specific application to Venezuela.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Passive cooling strategies for buildings in hot climates with specific application to Venezuela./
Author:
La Roche, Pablo Miguel.
Description:
249 p.
Notes:
Source: Dissertation Abstracts International, Volume: 65-10, Section: A, page: 3600.
Contained By:
Dissertation Abstracts International65-10A.
Subject:
Architecture. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3149818
ISBN:
0496090739
Passive cooling strategies for buildings in hot climates with specific application to Venezuela.
La Roche, Pablo Miguel.
Passive cooling strategies for buildings in hot climates with specific application to Venezuela.
- 249 p.
Source: Dissertation Abstracts International, Volume: 65-10, Section: A, page: 3600.
Thesis (Ph.D.)--University of California, Los Angeles, 2004.
In most developing countries mechanical air conditioning is expensive and out of reach of low income and many middle income families. An alternative are passive cooling systems, which can be built at lower costs, using local labor and resources, while generating income that stays in the community. Three passive cooling systems have been tested in this dissertation to determine their applicability in warm climates. A smart shading system that can be combined with all of these systems has also been tested.
ISBN: 0496090739Subjects--Topical Terms:
523581
Architecture.
Passive cooling strategies for buildings in hot climates with specific application to Venezuela.
LDR
:03279nmm 2200349 4500
001
1839352
005
20050627125022.5
008
130614s2004 eng d
020
$a
0496090739
035
$a
(UnM)AAI3149818
035
$a
AAI3149818
040
$a
UnM
$c
UnM
100
1
$a
La Roche, Pablo Miguel.
$3
1927748
245
1 0
$a
Passive cooling strategies for buildings in hot climates with specific application to Venezuela.
300
$a
249 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-10, Section: A, page: 3600.
500
$a
Chair: Murray Milne.
502
$a
Thesis (Ph.D.)--University of California, Los Angeles, 2004.
520
$a
In most developing countries mechanical air conditioning is expensive and out of reach of low income and many middle income families. An alternative are passive cooling systems, which can be built at lower costs, using local labor and resources, while generating income that stays in the community. Three passive cooling systems have been tested in this dissertation to determine their applicability in warm climates. A smart shading system that can be combined with all of these systems has also been tested.
520
$a
An intelligent automatic control system that manages air flow according to cooling needs in a building and resources in the outdoor environment was designed to manage nocturnal ventilative cooling (night flushing) and daytime comfort ventilation (economizer cooling). Results indicate that when outdoor conditions are suitable and the building has sufficient thermal mass, this is an inexpensive cooling system that can save energy and maintain indoor air temperature inside comfort boundaries.
520
$a
The smart controller was also used to manipulate an operable shading system which was tested inside and outside the test cell's window. This system reduced the indoor maximum temperature of the experimental cell compared to the control cell. Hourly data recorded in these cells was used to validate HEED, a whole-building energy simulation program and model the performance of these shades in California's climate zones.
520
$a
An operable radiant cooling system was tested with different configurations of mass and insulation. The position of the mass inside the space, the amount of solar radiation and the insulation level of the walls affected the temperature distribution and swing inside the cell. Equations that predicted indoor maximum temperature from the recorded experimental results have been developed.
520
$a
An indirect evaporative cooling system was also tested and proved to be a reliable cooling source. Its performance is a function of the outdoor average wet bulb temperature. Equations that predicted indoor maximum temperature from the recorded experimental results have been developed.
520
$a
This dissertation demonstrates that the performance of all the systems can be boosted with smart controllers that take advantage of instantaneous climate conditions.
590
$a
School code: 0031.
650
4
$a
Architecture.
$3
523581
650
4
$a
Landscape Architecture.
$3
890923
650
4
$a
Engineering, Mechanical.
$3
783786
690
$a
0729
690
$a
0390
690
$a
0548
710
2 0
$a
University of California, Los Angeles.
$3
626622
773
0
$t
Dissertation Abstracts International
$g
65-10A.
790
1 0
$a
Milne, Murray,
$e
advisor
790
$a
0031
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3149818
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9188866
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login