Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Removal of bioaerosols at varied hum...
~
Wang, Min.
Linked to FindBook
Google Book
Amazon
博客來
Removal of bioaerosols at varied humidities by glasswool filter.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Removal of bioaerosols at varied humidities by glasswool filter./
Author:
Wang, Min.
Description:
205 p.
Notes:
Source: Dissertation Abstracts International, Volume: 67-01, Section: B, page: 0470.
Contained By:
Dissertation Abstracts International67-01B.
Subject:
Engineering, Environmental. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3200341
ISBN:
9780542472985
Removal of bioaerosols at varied humidities by glasswool filter.
Wang, Min.
Removal of bioaerosols at varied humidities by glasswool filter.
- 205 p.
Source: Dissertation Abstracts International, Volume: 67-01, Section: B, page: 0470.
Thesis (Ph.D.)--University of Kentucky, 2005.
This study presents the creation and evaluation of a high-strength, wet aerosol signal containing surrogate viruses and bacteria into a system capable of detecting several logs of removal by filtration. The system consisted of a collision six jet nebulizer, a copper pipe pre-mixing chamber (1" diameter and 32.7" length), a plexi-glass stabilization chamber (3.4" diameter and 9.6" length), and a collection system comprised of a glass impinger with Teflon filter. The partial pressure for the nebulizer was 10 psi, and the total flow rate through the system was 6 L/min. The system was evaluated multiple times using a cocktail signal of E. coli bacteria, MS2 coliphage (27 mn) and PRD1 bacteriophage (62 nm). The dosed viable counts of the surrogates in the nebulizer were around 10 9 colonies/mL for E. coli, and 109 pfu/mL for MS2 and PRD1. A strong signal was reliably recovered from the collection system (106 colonies/L air and 106∼107 pfu/L air for bacteria and bacteriophage, respectively) during 5-minute sampling. The system was capable of generating stable and reproducible bioaerosol signals.
ISBN: 9780542472985Subjects--Topical Terms:
783782
Engineering, Environmental.
Removal of bioaerosols at varied humidities by glasswool filter.
LDR
:03114nmm 2200289 4500
001
1824349
005
20061130141913.5
008
130610s2005 eng d
020
$a
9780542472985
035
$a
(UnM)AAI3200341
035
$a
AAI3200341
040
$a
UnM
$c
UnM
100
1
$a
Wang, Min.
$3
1254867
245
1 0
$a
Removal of bioaerosols at varied humidities by glasswool filter.
300
$a
205 p.
500
$a
Source: Dissertation Abstracts International, Volume: 67-01, Section: B, page: 0470.
500
$a
Director: Gail M. Brion.
502
$a
Thesis (Ph.D.)--University of Kentucky, 2005.
520
$a
This study presents the creation and evaluation of a high-strength, wet aerosol signal containing surrogate viruses and bacteria into a system capable of detecting several logs of removal by filtration. The system consisted of a collision six jet nebulizer, a copper pipe pre-mixing chamber (1" diameter and 32.7" length), a plexi-glass stabilization chamber (3.4" diameter and 9.6" length), and a collection system comprised of a glass impinger with Teflon filter. The partial pressure for the nebulizer was 10 psi, and the total flow rate through the system was 6 L/min. The system was evaluated multiple times using a cocktail signal of E. coli bacteria, MS2 coliphage (27 mn) and PRD1 bacteriophage (62 nm). The dosed viable counts of the surrogates in the nebulizer were around 10 9 colonies/mL for E. coli, and 109 pfu/mL for MS2 and PRD1. A strong signal was reliably recovered from the collection system (106 colonies/L air and 106∼107 pfu/L air for bacteria and bacteriophage, respectively) during 5-minute sampling. The system was capable of generating stable and reproducible bioaerosol signals.
520
$a
The removal efficiency for E. coli and MS2 using the glasswool filter was at least 5-log removal at indoor humidity (20%-50%) and room temperature (20°C). The Relative Humidity (RH) did not affect the removal efficiency of E. coli at the beginning of filtration, but over time. RH affected the removal efficiency of MS2 at the earlier stage of filtration, which the removal efficiency was greater at 50% RH than 23% RH. MS2 also did not associate with E. coli in the aerosols to a great extent since they have different, distinctive breakthrough pattern.
520
$a
This study found that generated bioaerosol signal was captured and recovered without significant loss by immediate extraction. It was also found that shaking deactivated approximately 34% PRD1, and drying at room humidity and temperature for only one hour deactivated approximately 2 logs PRD1 captured on glasswool filters. Shaking did not affect the viability of MS2 and there was less than one-log deactivation even after more than 24-hour drying at room temperature for MS2. Therefore, MS2 was a better viral surrogate for wet bioaerosol study than PRD1.
590
$a
School code: 0102.
650
4
$a
Engineering, Environmental.
$3
783782
690
$a
0775
710
2 0
$a
University of Kentucky.
$3
1017485
773
0
$t
Dissertation Abstracts International
$g
67-01B.
790
1 0
$a
Brion, Gail M.,
$e
advisor
790
$a
0102
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3200341
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9215212
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login