Modeling and control of a direct expansion (DX) variable-air-volume (VAV) air conditioning (A/C) system.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Modeling and control of a direct expansion (DX) variable-air-volume (VAV) air conditioning (A/C) system./
作者:
Chen, Wu.
面頁冊數:
222 p.
附註:
Source: Dissertation Abstracts International, Volume: 66-11, Section: B, page: 6227.
Contained By:
Dissertation Abstracts International66-11B.
標題:
Engineering, Mechanical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3195395
ISBN:
9780542402470
Modeling and control of a direct expansion (DX) variable-air-volume (VAV) air conditioning (A/C) system.
Chen, Wu.
Modeling and control of a direct expansion (DX) variable-air-volume (VAV) air conditioning (A/C) system.
- 222 p.
Source: Dissertation Abstracts International, Volume: 66-11, Section: B, page: 6227.
Thesis (Ph.D.)--Hong Kong Polytechnic University (People's Republic of China), 2005.
A direct expansion (DX) variable-air-volume (VAV) air conditioning (A/C) system, a typical type of air-cooled packaged A/C systems found in commercial buildings, consists of a VAV air-distribution sub-system and a DX refrigeration plant. Currently, the major deterrence to its wider application is to continuously match the output cooling capacity from its DX refrigeration plant with the varying cooling load in its VAV air-distribution sub-system.
ISBN: 9780542402470Subjects--Topical Terms:
783786
Engineering, Mechanical.
Modeling and control of a direct expansion (DX) variable-air-volume (VAV) air conditioning (A/C) system.
LDR
:03355nmm 2200313 4500
001
1821291
005
20061115073001.5
008
130610s2005 eng d
020
$a
9780542402470
035
$a
(UnM)AAI3195395
035
$a
AAI3195395
040
$a
UnM
$c
UnM
100
1
$a
Chen, Wu.
$3
1910481
245
1 0
$a
Modeling and control of a direct expansion (DX) variable-air-volume (VAV) air conditioning (A/C) system.
300
$a
222 p.
500
$a
Source: Dissertation Abstracts International, Volume: 66-11, Section: B, page: 6227.
500
$a
Adviser: Shiming Deng.
502
$a
Thesis (Ph.D.)--Hong Kong Polytechnic University (People's Republic of China), 2005.
520
$a
A direct expansion (DX) variable-air-volume (VAV) air conditioning (A/C) system, a typical type of air-cooled packaged A/C systems found in commercial buildings, consists of a VAV air-distribution sub-system and a DX refrigeration plant. Currently, the major deterrence to its wider application is to continuously match the output cooling capacity from its DX refrigeration plant with the varying cooling load in its VAV air-distribution sub-system.
520
$a
This thesis firstly reports on the development of an experimental rig for a DX VAV A/C system. The rig was operated by a computerized logging and control supervisory system.
520
$a
Secondly, a complete dynamic mathematical model for the experimental DX VAV A/C system has been developed based on the principle of mass and energy conservation, and using the correlations describing the operational performance of various components in the experimental DX VAV A/C system. The model was component-based and of partial-lumped-parameter type. Both the steady-state and dynamic behaviors from both the DX refrigeration plant and the VAV sub-system can be simultaneously simulated by the model.
520
$a
Thirdly, the experimental validation for the dynamic model developed using the experimental rig is presented. The open-loop responses from both the DX refrigeration plant and the dynamic sub-model representing the DX plant were compared and found in good agreement. Fourthly, the thesis reports on the simulated closed-loop responses from the DX VAV A/C system with all its conventional proportional-integral control loops being enabled, using the validated model. Simulation results demonstrated that the dynamic model developed can behave as expected in a similar manner to a real DX VAV A/C system with all its control loops enabled.
520
$a
Finally, the development of a novel DDC-based feedforward capacity controller, for matching the output cooling capacity from the DX refrigeration plant with the varying cooling load in the VAV sub-system, is reported. The feedforward controller consisted of both a numerical calculation algorithm, and a dead-band for avoiding unstable compressor operation. Controllability tests for the feedforward controller have been carried out in the experimental rig. Test results suggested that the novel feedforward controller developed was able to provide satisfactory control sensitivity and accuracy.
590
$a
School code: 1170.
650
4
$a
Engineering, Mechanical.
$3
783786
690
$a
0548
710
2 0
$a
Hong Kong Polytechnic University (People's Republic of China).
$3
1288341
773
0
$t
Dissertation Abstracts International
$g
66-11B.
790
1 0
$a
Deng, Shiming,
$e
advisor
790
$a
1170
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3195395
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9212154
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入