Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Miniaturization and application of d...
~
Berman, Elena S. F.
Linked to FindBook
Google Book
Amazon
博客來
Miniaturization and application of direct-liquid cavity ring-down spectroscopy.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Miniaturization and application of direct-liquid cavity ring-down spectroscopy./
Author:
Berman, Elena S. F.
Description:
125 p.
Notes:
Source: Dissertation Abstracts International, Volume: 65-11, Section: B, page: 5742.
Contained By:
Dissertation Abstracts International65-11B.
Subject:
Chemistry, Physical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3153526
ISBN:
0496139266
Miniaturization and application of direct-liquid cavity ring-down spectroscopy.
Berman, Elena S. F.
Miniaturization and application of direct-liquid cavity ring-down spectroscopy.
- 125 p.
Source: Dissertation Abstracts International, Volume: 65-11, Section: B, page: 5742.
Thesis (Ph.D.)--Stanford University, 2005.
500 when in production.Cavity ring-down spectroscopy (CRDS) is a relatively new analytical technique for making sensitive absorption measurements. CRDS involves the use of highly reflective mirrors to form an optical cavity into which the sample of interest is placed. Light injected into the optical cavity undergoes an exponential decay of intensity. Absorption measurements can be made by measuring a change in the lifetime of the exponential decay when the sample is present. This thesis describes the extension of CRDS to the liquid phase using a direct-liquid approach. Direct-liquid CRDS (DL-CRDS) entails filling the optical cavity completely with the solution of interest, allowing the mirrors to serve as the ends of the liquid container. This design eliminates losses caused by container interfaces and provides a long path-length through the sample. Design and characterization of the instrumentation are described and an in-depth analysis of the treatment of the experimental data is presented. Miniaturization towards eventual field-instrument production has resulted in a tabletop instrument that is quite compact and is estimated to cost less than
ISBN: 0496139266Subjects--Topical Terms:
560527
Chemistry, Physical.
Miniaturization and application of direct-liquid cavity ring-down spectroscopy.
LDR
:03262nmm 2200289 4500
001
1819429
005
20061005085846.5
008
130610s2005 eng d
020
$a
0496139266
035
$a
(UnM)AAI3153526
035
$a
AAI3153526
040
$a
UnM
$c
UnM
100
1
$a
Berman, Elena S. F.
$3
1908709
245
1 0
$a
Miniaturization and application of direct-liquid cavity ring-down spectroscopy.
300
$a
125 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-11, Section: B, page: 5742.
500
$a
Adviser: Richard N. Zare.
502
$a
Thesis (Ph.D.)--Stanford University, 2005.
520
$a
Cavity ring-down spectroscopy (CRDS) is a relatively new analytical technique for making sensitive absorption measurements. CRDS involves the use of highly reflective mirrors to form an optical cavity into which the sample of interest is placed. Light injected into the optical cavity undergoes an exponential decay of intensity. Absorption measurements can be made by measuring a change in the lifetime of the exponential decay when the sample is present. This thesis describes the extension of CRDS to the liquid phase using a direct-liquid approach. Direct-liquid CRDS (DL-CRDS) entails filling the optical cavity completely with the solution of interest, allowing the mirrors to serve as the ends of the liquid container. This design eliminates losses caused by container interfaces and provides a long path-length through the sample. Design and characterization of the instrumentation are described and an in-depth analysis of the treatment of the experimental data is presented. Miniaturization towards eventual field-instrument production has resulted in a tabletop instrument that is quite compact and is estimated to cost less than
$3
500 when in production.
520
$a
The direct-liquid CRDS instrument is shown to sensitively detect water in organic solvents in the 1- to 100-parts-per-thousand (ppt) range with excellent linearity. The absorptivity of water at 660 nm in acetone and acetonitrile is found to be 2.0 x 10-5 ppt -1 cm-1. As expected, the absorptivity of water in tetrahydrofuran is similar. Additional experiments use the DL-CRDS setup to study the kinetics of the reduction of methylene blue by ascorbic acid in acetonitrile. The sensitivity of DL-CRDS allows kinetic monitoring of reactions at extremely low concentrations and in solvents that would otherwise be unavailable due to solubility concerns. In this case, nanomolar concentrations of methylene blue and micromolar concentrations of ascorbic acid produced pseudo first-order kinetics. The overall reduction was found to have a first-order dependence on both methylene blue and ascorbic acid concentrations, with an experimentally determined rate constant of 2.7 +/- 0.5 x 10 3 M-1 s-1. Several additional applications are suggested to take advantage of the high sensitivity, robustness, and good time resolution of the tabletop, direct-liquid cavity ring-down spectroscopy instrument.
590
$a
School code: 0212.
650
4
$a
Chemistry, Physical.
$3
560527
650
4
$a
Chemistry, Analytical.
$3
586156
690
$a
0494
690
$a
0486
710
2 0
$a
Stanford University.
$3
754827
773
0
$t
Dissertation Abstracts International
$g
65-11B.
790
1 0
$a
Zare, Richard N.,
$e
advisor
790
$a
0212
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3153526
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9210292
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login