Image registration for patient positioning in external beam radiotherapy.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Image registration for patient positioning in external beam radiotherapy./
作者:
Wu, Jian.
面頁冊數:
168 p.
附註:
Source: Dissertation Abstracts International, Volume: 66-01, Section: B, page: 0397.
Contained By:
Dissertation Abstracts International66-01B.
標題:
Engineering, Biomedical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3161642
ISBN:
0496952757
Image registration for patient positioning in external beam radiotherapy.
Wu, Jian.
Image registration for patient positioning in external beam radiotherapy.
- 168 p.
Source: Dissertation Abstracts International, Volume: 66-01, Section: B, page: 0397.
Thesis (Ph.D.)--The University of Tennessee Health Science Center, 2005.
This project aims at development of image registration techniques using electronic portal imaging device (EPID) imaging for automated on-line patient positioning in radiation therapy. The project consists of two parts. In part one, we developed an iterative subregion match (ISM) algorithm and a variable step-size grid search (VSGS) algorithm. The ISM was applied to intramodal registrations involving EPID images. User intervention is limited to selection of rectangular subregions in the reference image. Phantom experiments show that the ISM algorithm has the accuracy of 0.2 mm and 0.2°. The registration takes typically 8 sec on a 2 GHz PC. The VSGS was applied to intermodal registrations involving digitally reconstructed radiographs (DRRs) and EPID images. It was combined with a multi-resolution strategy to increase computation speed without adversely affecting robustness. Measurements indicated that VSGS has an accuracy of 0.5 mm and 0.5°, and requires about 8 seconds on a 2 GHz PC. Validation was carried out using phantom and clinical imaging data from a video camera-based EPID and amorphous silicon flat-panel system with 6 MV megavoltage x-rays.
ISBN: 0496952757Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Image registration for patient positioning in external beam radiotherapy.
LDR
:03213nmm 2200277 4500
001
1816981
005
20060816133853.5
008
130610s2005 eng d
020
$a
0496952757
035
$a
(UnM)AAI3161642
035
$a
AAI3161642
040
$a
UnM
$c
UnM
100
1
$a
Wu, Jian.
$3
1279362
245
1 0
$a
Image registration for patient positioning in external beam radiotherapy.
300
$a
168 p.
500
$a
Source: Dissertation Abstracts International, Volume: 66-01, Section: B, page: 0397.
500
$a
Adviser: Sanjiv Samant.
502
$a
Thesis (Ph.D.)--The University of Tennessee Health Science Center, 2005.
520
$a
This project aims at development of image registration techniques using electronic portal imaging device (EPID) imaging for automated on-line patient positioning in radiation therapy. The project consists of two parts. In part one, we developed an iterative subregion match (ISM) algorithm and a variable step-size grid search (VSGS) algorithm. The ISM was applied to intramodal registrations involving EPID images. User intervention is limited to selection of rectangular subregions in the reference image. Phantom experiments show that the ISM algorithm has the accuracy of 0.2 mm and 0.2°. The registration takes typically 8 sec on a 2 GHz PC. The VSGS was applied to intermodal registrations involving digitally reconstructed radiographs (DRRs) and EPID images. It was combined with a multi-resolution strategy to increase computation speed without adversely affecting robustness. Measurements indicated that VSGS has an accuracy of 0.5 mm and 0.5°, and requires about 8 seconds on a 2 GHz PC. Validation was carried out using phantom and clinical imaging data from a video camera-based EPID and amorphous silicon flat-panel system with 6 MV megavoltage x-rays.
520
$a
In part two, the concept of registration quality evaluator (RQE) was introduced. The RQE consists of a decision criterion to determine the acceptability of registration results. It is generated using initial training data generated from a single pair of reference and target images to which known shifts are applied and similarity measures are computed. The RQE was applied to patient positioning in cranial radiotherapy using an anthropomorphic phantom. Two types of RQEs were constructed---one for the EPID/EPID registration and the other for the DRR/EPID registration. Using receiver operating characteristic (ROC) analysis, mutual information was proved to be an appropriate similarity measure for both types of RQEs. We also established a methodology in the estimation of the performance of a RQE by calculating the sensitivity and the specificity and their confidence intervals. These estimations were confirmed using phantom imaging with radio-opaque fiducial markers. RQE combined with a fast and accurate registration algorithm offers the potential of a robust automated patient positioning system with reduced user intervention.
590
$a
School code: 0783.
650
4
$a
Engineering, Biomedical.
$3
1017684
690
$a
0541
710
2 0
$a
The University of Tennessee Health Science Center.
$3
1262886
773
0
$t
Dissertation Abstracts International
$g
66-01B.
790
1 0
$a
Samant, Sanjiv,
$e
advisor
790
$a
0783
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3161642
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9207844
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入