語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Physics of tissue harmonic imaging b...
~
Jing, Yuan.
FindBook
Google Book
Amazon
博客來
Physics of tissue harmonic imaging by ultrasound.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Physics of tissue harmonic imaging by ultrasound./
作者:
Jing, Yuan.
面頁冊數:
153 p.
附註:
Source: Dissertation Abstracts International, Volume: 65-12, Section: B, page: 6431.
Contained By:
Dissertation Abstracts International65-12B.
標題:
Physics, Acoustics. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3157382
ISBN:
0496901311
Physics of tissue harmonic imaging by ultrasound.
Jing, Yuan.
Physics of tissue harmonic imaging by ultrasound.
- 153 p.
Source: Dissertation Abstracts International, Volume: 65-12, Section: B, page: 6431.
Thesis (Ph.D.)--Boston University, 2005.
Tissue Harmonic Imaging (THI) is an imaging modality that is currently deployed on diagnostic ultrasound scanners. In THI the amplitude of the ultrasonic pulse that is used to probe the tissue is large enough that the pulse undergoes nonlinear distortion as it propagates into the tissue. One result of the distortion is that as the pulse propagates energy is shifted from the fundamental frequency of the source pulse into its higher harmonics. These harmonics will scatter off objects in the tissue and images formed from the scattered higher harmonics are considered to have superior quality to the images formed from the fundamental frequency. Processes that have been suggested as possibly responsible for the improved imaging in THI include: (1) reduced sensitivity to reverberation, (2) reduced sensitivity to aberration, and (3) reduction in side lobes. By using a combination of controlled experiments and numerical simulations, these three reasons have been investigated. A single element transducer and a clinical ultrasound scanner with a phased array transducer were used to image a commercial tissue-mimicking phantom with calibrated targets. The higher image quality achieved with THI was quantified in terms of spatial resolution and "clutter" signals. A three-dimensional model of the forward propagation of nonlinear sound beams in media with arbitrary spatial properties (a generalized KZK equation) was developed. A time-domain code for solving the KZK equation was validated with measurements of the acoustic field generated by the single element transducer and the phased array transducer. The code was used to investigate the impact of aberration using tissue-like media with three-dimensional variations in all acoustic properties. The three-dimensional maps of tissue properties were derived from the datasets available through the Visible Female project. The experiments and simulations demonstrated that second harmonic imaging (1) suffers less clutter associated with reverberation; (2) is not immune to aberration effects and (3) suffers less clutter due to reduced side-lobe levels. The results indicate that side lobe suppression is the most significant reason for the improvement of second harmonic imaging.
ISBN: 0496901311Subjects--Topical Terms:
1019086
Physics, Acoustics.
Physics of tissue harmonic imaging by ultrasound.
LDR
:03128nmm 2200289 4500
001
1816973
005
20060816133850.5
008
130610s2005 eng d
020
$a
0496901311
035
$a
(UnM)AAI3157382
035
$a
AAI3157382
040
$a
UnM
$c
UnM
100
1
$a
Jing, Yuan.
$3
1906341
245
1 0
$a
Physics of tissue harmonic imaging by ultrasound.
300
$a
153 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-12, Section: B, page: 6431.
500
$a
Major Professor: Robin O. Cleveland.
502
$a
Thesis (Ph.D.)--Boston University, 2005.
520
$a
Tissue Harmonic Imaging (THI) is an imaging modality that is currently deployed on diagnostic ultrasound scanners. In THI the amplitude of the ultrasonic pulse that is used to probe the tissue is large enough that the pulse undergoes nonlinear distortion as it propagates into the tissue. One result of the distortion is that as the pulse propagates energy is shifted from the fundamental frequency of the source pulse into its higher harmonics. These harmonics will scatter off objects in the tissue and images formed from the scattered higher harmonics are considered to have superior quality to the images formed from the fundamental frequency. Processes that have been suggested as possibly responsible for the improved imaging in THI include: (1) reduced sensitivity to reverberation, (2) reduced sensitivity to aberration, and (3) reduction in side lobes. By using a combination of controlled experiments and numerical simulations, these three reasons have been investigated. A single element transducer and a clinical ultrasound scanner with a phased array transducer were used to image a commercial tissue-mimicking phantom with calibrated targets. The higher image quality achieved with THI was quantified in terms of spatial resolution and "clutter" signals. A three-dimensional model of the forward propagation of nonlinear sound beams in media with arbitrary spatial properties (a generalized KZK equation) was developed. A time-domain code for solving the KZK equation was validated with measurements of the acoustic field generated by the single element transducer and the phased array transducer. The code was used to investigate the impact of aberration using tissue-like media with three-dimensional variations in all acoustic properties. The three-dimensional maps of tissue properties were derived from the datasets available through the Visible Female project. The experiments and simulations demonstrated that second harmonic imaging (1) suffers less clutter associated with reverberation; (2) is not immune to aberration effects and (3) suffers less clutter due to reduced side-lobe levels. The results indicate that side lobe suppression is the most significant reason for the improvement of second harmonic imaging.
590
$a
School code: 0017.
650
4
$a
Physics, Acoustics.
$3
1019086
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Engineering, Mechanical.
$3
783786
690
$a
0986
690
$a
0541
690
$a
0548
710
2 0
$a
Boston University.
$3
1017454
773
0
$t
Dissertation Abstracts International
$g
65-12B.
790
1 0
$a
Cleveland, Robin O.,
$e
advisor
790
$a
0017
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3157382
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9207836
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入