Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Multiple gradient echo propeller (MG...
~
Poonawalla, Aziz Hatim.
Linked to FindBook
Google Book
Amazon
博客來
Multiple gradient echo propeller (MGREP) MRI: Technical development and potential applications.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Multiple gradient echo propeller (MGREP) MRI: Technical development and potential applications./
Author:
Poonawalla, Aziz Hatim.
Description:
199 p.
Notes:
Source: Dissertation Abstracts International, Volume: 66-03, Section: B, page: 1346.
Contained By:
Dissertation Abstracts International66-03B.
Subject:
Biophysics, Medical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3168445
ISBN:
0542042177
Multiple gradient echo propeller (MGREP) MRI: Technical development and potential applications.
Poonawalla, Aziz Hatim.
Multiple gradient echo propeller (MGREP) MRI: Technical development and potential applications.
- 199 p.
Source: Dissertation Abstracts International, Volume: 66-03, Section: B, page: 1346.
Thesis (Ph.D.)--The University of Texas Graduate School of Biomedical Sciences at Houston, 2005.
The PROPELLER (Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction) magnetic resonance imaging (MRI) technique has inherent advantages over other fast imaging methods, including robust motion correction, reduced image distortion, and resistance to off-resonance effects. These features make PROPELLER highly desirable for T2*-sensitive imaging, high-resolution diffusion imaging, and many other applications. However, PROPELLER has been predominantly implemented as a fast spin-echo (FSE) technique, which is insensitive to T2* contrast, and requires time-inefficient signal averaging to achieve adequate signal-to-noise ratio (SNR) for many applications. These issues presently constrain the potential clinical utility of FSE-based PROPELLER.
ISBN: 0542042177Subjects--Topical Terms:
1017681
Biophysics, Medical.
Multiple gradient echo propeller (MGREP) MRI: Technical development and potential applications.
LDR
:03411nmm 2200313 4500
001
1816523
005
20060717100352.5
008
130610s2005 eng d
020
$a
0542042177
035
$a
(UnM)AAI3168445
035
$a
AAI3168445
040
$a
UnM
$c
UnM
100
1
$a
Poonawalla, Aziz Hatim.
$3
1905901
245
1 0
$a
Multiple gradient echo propeller (MGREP) MRI: Technical development and potential applications.
300
$a
199 p.
500
$a
Source: Dissertation Abstracts International, Volume: 66-03, Section: B, page: 1346.
500
$a
Supervisor: Xiaohong Joe Zhou.
502
$a
Thesis (Ph.D.)--The University of Texas Graduate School of Biomedical Sciences at Houston, 2005.
520
$a
The PROPELLER (Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction) magnetic resonance imaging (MRI) technique has inherent advantages over other fast imaging methods, including robust motion correction, reduced image distortion, and resistance to off-resonance effects. These features make PROPELLER highly desirable for T2*-sensitive imaging, high-resolution diffusion imaging, and many other applications. However, PROPELLER has been predominantly implemented as a fast spin-echo (FSE) technique, which is insensitive to T2* contrast, and requires time-inefficient signal averaging to achieve adequate signal-to-noise ratio (SNR) for many applications. These issues presently constrain the potential clinical utility of FSE-based PROPELLER.
520
$a
In this research, our aim was to extend and enhance the potential applications of PROPELLER MRI by developing a novel multiple gradient echo PROPELLER (MGREP) technique that can overcome the aforementioned limitations. The MGREP pulse sequence was designed to acquire multiple gradient-echo images simultaneously, without any increase in total scan time or RF energy deposition relative to FSE-based PROPELLER. A new parameter was also introduced for direct user-control over gradient echo spacing, to allow variable sensitivity to T2* contrast. In parallel to pulse sequence development, an improved algorithm for motion correction was also developed and evaluated against the established method through extensive simulations. The potential advantages of MGREP over FSE-based PROPELLER were illustrated via three specific applications: (1) quantitative T2* measurement, (2) time-efficient signal averaging, and (3) high-resolution diffusion imaging. Relative to the FSE-PROPELLER method, the MGREP sequence was found to yield quantitative T2* values, increase SNR by ∼40% without any increase in acquisition time or RF energy deposition, and noticeably improve image quality in high-resolution diffusion maps. In addition, the new motion algorithm was found to improve the performance considerably in motion-artifact reduction.
520
$a
Overall, this work demonstrated a number of enhancements and extensions to existing PROPELLER techniques. The new technical capabilities of PROPELLER imaging, developed in this thesis research, are expected to serve as the foundation for further expanding the scope of PROPELLER applications.
590
$a
School code: 2034.
650
4
$a
Biophysics, Medical.
$3
1017681
650
4
$a
Physics, General.
$3
1018488
650
4
$a
Engineering, Biomedical.
$3
1017684
690
$a
0760
690
$a
0605
690
$a
0541
710
2 0
$a
The University of Texas Graduate School of Biomedical Sciences at Houston.
$3
1019338
773
0
$t
Dissertation Abstracts International
$g
66-03B.
790
1 0
$a
Zhou, Xiaohong Joe,
$e
advisor
790
$a
2034
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3168445
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9207386
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login