Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Commercialized university research--...
~
Rivera, Michael J.
Linked to FindBook
Google Book
Amazon
博客來
Commercialized university research---a study of antecedents and outcomes and the innovation leading practices of entrepreneurs.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Commercialized university research---a study of antecedents and outcomes and the innovation leading practices of entrepreneurs./
Author:
Rivera, Michael J.
Description:
157 p.
Notes:
Source: Dissertation Abstracts International, Volume: 71-09, Section: A, page: 3329.
Contained By:
Dissertation Abstracts International71-09A.
Subject:
Business Administration, Entrepreneurship. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3413959
ISBN:
9781124156392
Commercialized university research---a study of antecedents and outcomes and the innovation leading practices of entrepreneurs.
Rivera, Michael J.
Commercialized university research---a study of antecedents and outcomes and the innovation leading practices of entrepreneurs.
- 157 p.
Source: Dissertation Abstracts International, Volume: 71-09, Section: A, page: 3329.
Thesis (Ph.D.)--Purdue University, 2010.
X-ray mammography is the most widely used breast cancer imaging technique. Although mammography has met with success, over 400,000 women newly diagnosed each year are still misdiagnosed and undergo a biopsy. Current mammography techniques are limited by: (1) low image contrast of lesions in dense breasts; (2) difficulty in diagnosing and detecting lesions close to the chest wall and in women with radiographically dense breasts; (3) structural overlap onto a two-dimensional (2D) image plane; and (4) patient discomfort due to breast compression. Therefore, three-dimensional (3D) tomographic breast imaging approaches for pendant, uncompressed breasts have been explored to overcome these limitations and improve the detection of breast lesions. The goal of this thesis is to implement and characterize a dual-modality SPECT-CT dedicated breast imaging system that can overcome these limitations and integrate both metabolic and anatomical information to further improve the visual quality and quantitative accuracy over independent systems alone.
ISBN: 9781124156392Subjects--Topical Terms:
1026793
Business Administration, Entrepreneurship.
Commercialized university research---a study of antecedents and outcomes and the innovation leading practices of entrepreneurs.
LDR
:05661nam 2200397 4500
001
1401431
005
20111020091953.5
008
130515s2010 ||||||||||||||||| ||eng d
020
$a
9781124156392
035
$a
(UMI)AAI3413959
035
$a
AAI3413959
040
$a
UMI
$c
UMI
100
1
$a
Rivera, Michael J.
$3
1680564
245
1 0
$a
Commercialized university research---a study of antecedents and outcomes and the innovation leading practices of entrepreneurs.
300
$a
157 p.
500
$a
Source: Dissertation Abstracts International, Volume: 71-09, Section: A, page: 3329.
500
$a
Adviser: Scott Homan.
502
$a
Thesis (Ph.D.)--Purdue University, 2010.
520
$a
X-ray mammography is the most widely used breast cancer imaging technique. Although mammography has met with success, over 400,000 women newly diagnosed each year are still misdiagnosed and undergo a biopsy. Current mammography techniques are limited by: (1) low image contrast of lesions in dense breasts; (2) difficulty in diagnosing and detecting lesions close to the chest wall and in women with radiographically dense breasts; (3) structural overlap onto a two-dimensional (2D) image plane; and (4) patient discomfort due to breast compression. Therefore, three-dimensional (3D) tomographic breast imaging approaches for pendant, uncompressed breasts have been explored to overcome these limitations and improve the detection of breast lesions. The goal of this thesis is to implement and characterize a dual-modality SPECT-CT dedicated breast imaging system that can overcome these limitations and integrate both metabolic and anatomical information to further improve the visual quality and quantitative accuracy over independent systems alone.
520
$a
Initial work on this thesis started out with characterizing the modulation transfer function (MTF) in 3D for the independent dedicated SPECT and CT systems. Using a novel phantom to measure the MTF at different locations in a 3D reconstructed volume, results indicated that acquiring images with a step-and-shoot mode and using trajectories (i.e. path the system travels as it moves around the object) that met the sampling criteria, uniform resolution throughout a 3D reconstructed volume can be obtained.
520
$a
The effects of cone-beam sampling and system geometry on the reconstructed CT images were investigated. As expected, constraining the x-ray source and detector to a circular tilt yielded insufficiently sampled reconstructed images, which contained geometric distortions, reconstruction inaccuracies, and cupping artifacts. Although beam hardening and scatter are considered to be the main causes of cupping artifacts in the reconstructed CT images, this study suggested that insufficient sampling might be a third cause to cupping artifacts in the reconstructed images. An additional finding in this study was that despite the insufficient sampling in the reconstructed CT images, high frequency information (edges, small objects) was preserved more than low frequency information (uniform area, large objects).
520
$a
Using a lateral offset geometry in CT, in which the system was shifted laterally from the center-of-rotation (COR), had been shown to introduce circular and cylindrical artifacts in the reconstructed coronal and sagittal CT slices, respectively. Monte Carlo studies showed that these artifacts were due to mechanical detector misalignment. However, cropping the projections, such that there was less of an overlap between conjugate projections, or placing the system in a centered geometry could eliminate these artifacts.
520
$a
Next, an integrated dual-modality SPECT-CT scanner was designed and built. The performance of this scanner was evaluated with geometric and anthropomorphic phantoms. Despite only having nearly complete sampling from both systems, results illustrated that SPECT and CT images can be registered and fused with minimal error.
520
$a
The feasibility of using the reconstructed CT images to quantify different tissue components was also investigated by using different materials as well as a cadaver (i.e., human breast). By implementing scatter correction using a developed beam stop approach, scatter corrected reconstructed images yielded attenuation coefficient values only with 7% error.
520
$a
Finally, four clinical studies were done to evaluate the effectiveness of the dual-modality scanner. Although the CT is currently limited in the amount of breast volume that can be imaged, reconstructed images appeared to have minimal distortion and reconstruction inaccuracy. Fused SPECT-CT images also illustrated the significance of using functional information from SPECT to help localize the lesion in the anatomical CT images.
520
$a
The dual-modality SPECT-CT scanner has successfully demonstrated its capability to uniformly sample an uncompressed breast with 3D complex trajectories that meet the sampling criteria and provide tissue quantification and localization information. This system has the potential to be a clinically useful imaging tool in detecting cancer, especially in women with high risk of breast cancer, monitoring treatment therapies, and improving surgical biopsy guidance.
590
$a
School code: 0183.
650
4
$a
Business Administration, Entrepreneurship.
$3
1026793
650
4
$a
Education, Higher.
$3
543175
690
$a
0429
690
$a
0745
710
2
$a
Purdue University.
$b
Technology.
$3
1022269
773
0
$t
Dissertation Abstracts International
$g
71-09A.
790
1 0
$a
Homan, Scott,
$e
advisor
790
1 0
$a
Mohler, James
$e
committee member
790
1 0
$a
Beyerlein, Michael
$e
committee member
790
1 0
$a
Boregowda, Satish
$e
committee member
790
$a
0183
791
$a
Ph.D.
792
$a
2010
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3413959
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9164570
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login