Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Light-activation influence on the th...
~
Srinivas, Raksha K.
Linked to FindBook
Google Book
Amazon
博客來
Light-activation influence on the thermal analysis of a resin-modified glass-ionomer.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Light-activation influence on the thermal analysis of a resin-modified glass-ionomer./
Author:
Srinivas, Raksha K.
Description:
122 p.
Notes:
Source: Masters Abstracts International, Volume: 48-04, page: 2204.
Contained By:
Masters Abstracts International48-04.
Subject:
Health Sciences, Dentistry. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1474702
ISBN:
9781109699883
Light-activation influence on the thermal analysis of a resin-modified glass-ionomer.
Srinivas, Raksha K.
Light-activation influence on the thermal analysis of a resin-modified glass-ionomer.
- 122 p.
Source: Masters Abstracts International, Volume: 48-04, page: 2204.
Thesis (M.S.)--Marquette University, 2010.
The acid-base and light polymerization reactions in resin modified glass ionomers (RMGI) have been shown to compete and possibly inhibit one another during early RMGI development. Earlier beginning times of light polymerization initiation may limit the acid-base reaction and if time allowed for the acid-base components to react is increased, the extent of light cure reaction may be lesser. The thermal behavior of a commercially available RMGI was investigated in relation to a light initiation regimen using a differential scanning calorimeter (DSC). The relationship between delay in light initiation or no light initiation and the resultant set matrix of the material was determined by subjecting the material to a dynamic temperature scan between 37°C and 300°C at 10°C/min. Different cure groups (n=10 per cure group for an immediate light cure group, 5 min and 10 min delay light cure groups, and a dark cure group) were stored for specific periods of time (30 min, 1 day, 1 week, 1 month and 3 months; n=10/time group) in an incubator at 100% relative humidity and 37°C. Specimen weight changes due to storage and weight loss due to DSC testing were also computed. The DSC thermograms displayed endothermic peaks reflective of material degradation and thus material structure. All groups of specimens had a characteristic single endothermic peak in the thermograms except the 30 min dark cure specimens which had two endothermic peaks in their thermogram. The endothermic peaks were mainly attributed to the dehydration of bound water in the matrix of the material. Significant differences in endothermic peak enthalpy and peak temperature were observed among the cure and time groups. The results suggest that, in general, the immediately light cured material is of differing structure compared to groups that allow the acid-base reaction to occur either due to delay in light curing or its absence. Additionally, changes in the endothermic peak over time were observed, indicating material maturation occurred and is likely due to changes in the ratio of bound to unbound water in the matrix. Interpretation of weight changes in storage show light curing reduced the moisture sensitivity of the RMGI.
ISBN: 9781109699883Subjects--Topical Terms:
1019378
Health Sciences, Dentistry.
Light-activation influence on the thermal analysis of a resin-modified glass-ionomer.
LDR
:03205nam 2200301 4500
001
1393210
005
20110311132633.5
008
130515s2010 ||||||||||||||||| ||eng d
020
$a
9781109699883
035
$a
(UMI)AAI1474702
035
$a
AAI1474702
040
$a
UMI
$c
UMI
100
1
$a
Srinivas, Raksha K.
$3
1671710
245
1 0
$a
Light-activation influence on the thermal analysis of a resin-modified glass-ionomer.
300
$a
122 p.
500
$a
Source: Masters Abstracts International, Volume: 48-04, page: 2204.
500
$a
Adviser: David W. Berzins.
502
$a
Thesis (M.S.)--Marquette University, 2010.
520
$a
The acid-base and light polymerization reactions in resin modified glass ionomers (RMGI) have been shown to compete and possibly inhibit one another during early RMGI development. Earlier beginning times of light polymerization initiation may limit the acid-base reaction and if time allowed for the acid-base components to react is increased, the extent of light cure reaction may be lesser. The thermal behavior of a commercially available RMGI was investigated in relation to a light initiation regimen using a differential scanning calorimeter (DSC). The relationship between delay in light initiation or no light initiation and the resultant set matrix of the material was determined by subjecting the material to a dynamic temperature scan between 37°C and 300°C at 10°C/min. Different cure groups (n=10 per cure group for an immediate light cure group, 5 min and 10 min delay light cure groups, and a dark cure group) were stored for specific periods of time (30 min, 1 day, 1 week, 1 month and 3 months; n=10/time group) in an incubator at 100% relative humidity and 37°C. Specimen weight changes due to storage and weight loss due to DSC testing were also computed. The DSC thermograms displayed endothermic peaks reflective of material degradation and thus material structure. All groups of specimens had a characteristic single endothermic peak in the thermograms except the 30 min dark cure specimens which had two endothermic peaks in their thermogram. The endothermic peaks were mainly attributed to the dehydration of bound water in the matrix of the material. Significant differences in endothermic peak enthalpy and peak temperature were observed among the cure and time groups. The results suggest that, in general, the immediately light cured material is of differing structure compared to groups that allow the acid-base reaction to occur either due to delay in light curing or its absence. Additionally, changes in the endothermic peak over time were observed, indicating material maturation occurred and is likely due to changes in the ratio of bound to unbound water in the matrix. Interpretation of weight changes in storage show light curing reduced the moisture sensitivity of the RMGI.
590
$a
School code: 0116.
650
4
$a
Health Sciences, Dentistry.
$3
1019378
650
4
$a
Engineering, Materials Science.
$3
1017759
690
$a
0567
690
$a
0794
710
2
$a
Marquette University.
$b
Dentistry.
$3
1671711
773
0
$t
Masters Abstracts International
$g
48-04.
790
1 0
$a
Berzins, David W.,
$e
advisor
790
1 0
$a
Roberts, Howard W.
$e
committee member
790
1 0
$a
Stafford, Gary L.
$e
committee member
790
$a
0116
791
$a
M.S.
792
$a
2010
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1474702
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9156349
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login