語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
到查詢結果
[ null ]
切換:
標籤
|
MARC模式
|
ISBD
Improving Heat Spreading in Adsorben...
~
Sommers, Emily Grace,
FindBook
Google Book
Amazon
博客來
Improving Heat Spreading in Adsorbent Beds in Adsorption-Based Air Conditioning Systems /
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Improving Heat Spreading in Adsorbent Beds in Adsorption-Based Air Conditioning Systems // Emily Grace Sommers.
作者:
Sommers, Emily Grace,
面頁冊數:
1 electronic resource (211 pages)
附註:
Source: Masters Abstracts International, Volume: 86-07.
Contained By:
Masters Abstracts International86-07.
標題:
Mechanical engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31636236
ISBN:
9798302170149
Improving Heat Spreading in Adsorbent Beds in Adsorption-Based Air Conditioning Systems /
Sommers, Emily Grace,
Improving Heat Spreading in Adsorbent Beds in Adsorption-Based Air Conditioning Systems /
Emily Grace Sommers. - 1 electronic resource (211 pages)
Source: Masters Abstracts International, Volume: 86-07.
There is a need for sustainable alternatives to high global warming potential refrigerants used in air conditioning. The Radicle Development Center developed a water-based adsorption air conditioning unit, but it suffers from a long generation (desorption) time and a high heat source temperature. These issues can potentially be mitigated by improving the thermal transport in the adsorbent bed through the addition of highly conducting stainless-steel pins. The aim of this research is therefore to evaluate the impact of an increased packed bed thermal conductivity on the generation time and heat source temperature of the system. This is done through adding highly conducting inclusions. This study determined the optimal volume fraction of inclusions is near the percolation threshold. Performance was determined to be optimal with an increasing inclusion distribution in Cartesian coordinates and a constant inclusion distribution in cylindrical coordinates. A maintained heat source temperature is associated with a 33% and 22% decrease in generation time in Cartesian and cylindrical coordinates, respectively. A maintained generation time is associated with a 9% and 6% decrease in heat source temperature in Cartesian and cylindrical coordinate systems, respectively.
English
ISBN: 9798302170149Subjects--Topical Terms:
649730
Mechanical engineering.
Subjects--Index Terms:
Desorption
Improving Heat Spreading in Adsorbent Beds in Adsorption-Based Air Conditioning Systems /
LDR
:02706nmm a22004453i 4500
001
2438715
005
20260727134413.5
006
m o d
007
cr|nu||||||||
008
261011s2024 miu||||||m |||||||eng d
020
$a
9798302170149
035
$a
(MiAaPQD)AAI31636236
035
$a
AAI31636236
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Sommers, Emily Grace,
$e
author.
$3
3830094
245
1 0
$a
Improving Heat Spreading in Adsorbent Beds in Adsorption-Based Air Conditioning Systems /
$c
Emily Grace Sommers.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2024
300
$a
1 electronic resource (211 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 86-07.
500
$a
Advisors: Wemhoff, Aaron P. Committee members: Ortega, Alfonso; Li, Calvin.
502
$b
M.S.
$c
Villanova University
$d
2024.
520
$a
There is a need for sustainable alternatives to high global warming potential refrigerants used in air conditioning. The Radicle Development Center developed a water-based adsorption air conditioning unit, but it suffers from a long generation (desorption) time and a high heat source temperature. These issues can potentially be mitigated by improving the thermal transport in the adsorbent bed through the addition of highly conducting stainless-steel pins. The aim of this research is therefore to evaluate the impact of an increased packed bed thermal conductivity on the generation time and heat source temperature of the system. This is done through adding highly conducting inclusions. This study determined the optimal volume fraction of inclusions is near the percolation threshold. Performance was determined to be optimal with an increasing inclusion distribution in Cartesian coordinates and a constant inclusion distribution in cylindrical coordinates. A maintained heat source temperature is associated with a 33% and 22% decrease in generation time in Cartesian and cylindrical coordinates, respectively. A maintained generation time is associated with a 9% and 6% decrease in heat source temperature in Cartesian and cylindrical coordinate systems, respectively.
546
$a
English
590
$a
School code: 0245
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Fluid mechanics.
$3
528155
650
4
$a
Applied physics.
$3
3343996
650
4
$a
Thermodynamics.
$3
517304
653
$a
Desorption
653
$a
Generation time
653
$a
Heat source temperature
653
$a
Heat spreading
653
$a
Packed bed
690
$a
0548
690
$a
0204
690
$a
0215
690
$a
0348
710
2
$a
Villanova University.
$b
Department of Mechanical Engineering.
$e
degree granting institution.
$3
3815506
720
1
$a
Wemhoff, Aaron P.
$e
degree supervisor.
773
0
$t
Masters Abstracts International
$g
86-07.
790
$a
0245
791
$a
M.S.
792
$a
2024
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31636236
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9534410
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入
(1)帳號:一般為「身分證號」;外籍生或交換生則為「學號」。 (2)密碼:預設為帳號末四碼。
帳號
.
密碼
.
請在此電腦上記得個人資料
取消
忘記密碼? (請注意!您必須已在系統登記E-mail信箱方能使用。)