語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
到查詢結果
[ null ]
切換:
標籤
|
MARC模式
|
ISBD
Fluid Velocity Sensors Made by Therm...
~
Hanna, Andre,
FindBook
Google Book
Amazon
博客來
Fluid Velocity Sensors Made by Thermal Spray /
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Fluid Velocity Sensors Made by Thermal Spray // Andre Hanna.
作者:
Hanna, Andre,
面頁冊數:
1 electronic resource (30 pages)
附註:
Source: Masters Abstracts International, Volume: 86-05.
Contained By:
Masters Abstracts International86-05.
標題:
Mechanical engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31559346
ISBN:
9798342756037
Fluid Velocity Sensors Made by Thermal Spray /
Hanna, Andre,
Fluid Velocity Sensors Made by Thermal Spray /
Andre Hanna. - 1 electronic resource (30 pages)
Source: Masters Abstracts International, Volume: 86-05.
Thermal spray technology was used to make rugged surface sensors to measure the velocity of fluid flowing over a metal plate. The sensor consisted of a spiral-shaped nichrome (NiCr) heater coil, approximately 17 mm in diameter, and a thermocouple, both made by wire-arc spray. Plasma spray was used to deposit an electrically insulating layer of alumina, ~300 µm thick, on a 316 stainless steel block. A 17 mm diameter heater coil was deposited on top of the alumina layer by spraying nichrome from a twin wire arc spray system through a 3D printed polymer mask. The resulting NiCr line was ~50 µm thick and 104 mm long, with an electrical resistance of approximately 20 Ω. A thermocouple junction was built next to the heater by inserting an insulated constantan wire through a vertical hole drilled in the steel block and spraying steel on the top of the hole to close it and form an electrical connection between the wire and the surrounding substrate. The junction of the wire and the steel formed a thermocouple whose output voltage was calibrated as a function of temperature A flow loop was built to calibrate the sensor by passing either air or ethylene glycol over it at velocities of up to 4.4 m/s. A series of 1 to 6 min long voltage pulses were applied to the heater, increasing its temperature by approximately 5°-10°C each time, before letting it cool. The surface temperature cooling rate was recorded by the surface thermocouple. A calibration curve was developed of fluid velocities as a function of time constants for cooling of the sensor.
English
ISBN: 9798342756037Subjects--Topical Terms:
649730
Mechanical engineering.
Subjects--Index Terms:
Fluid velocity measurement
Fluid Velocity Sensors Made by Thermal Spray /
LDR
:02897nmm a22004333i 4500
001
2438676
005
20260727134408.5
006
m o d
007
cr|nu||||||||
008
261011s2024 miu||||||m |||||||eng d
020
$a
9798342756037
035
$a
(MiAaPQD)AAI31559346
035
$a
AAI31559346
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Hanna, Andre,
$e
author.
$3
3830050
245
1 0
$a
Fluid Velocity Sensors Made by Thermal Spray /
$c
Andre Hanna.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2024
300
$a
1 electronic resource (30 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Masters Abstracts International, Volume: 86-05.
500
$a
Advisors: Chandra, Sanjeev.
502
$b
M.A.S.
$c
University of Toronto (Canada)
$d
2024.
520
$a
Thermal spray technology was used to make rugged surface sensors to measure the velocity of fluid flowing over a metal plate. The sensor consisted of a spiral-shaped nichrome (NiCr) heater coil, approximately 17 mm in diameter, and a thermocouple, both made by wire-arc spray. Plasma spray was used to deposit an electrically insulating layer of alumina, ~300 µm thick, on a 316 stainless steel block. A 17 mm diameter heater coil was deposited on top of the alumina layer by spraying nichrome from a twin wire arc spray system through a 3D printed polymer mask. The resulting NiCr line was ~50 µm thick and 104 mm long, with an electrical resistance of approximately 20 Ω. A thermocouple junction was built next to the heater by inserting an insulated constantan wire through a vertical hole drilled in the steel block and spraying steel on the top of the hole to close it and form an electrical connection between the wire and the surrounding substrate. The junction of the wire and the steel formed a thermocouple whose output voltage was calibrated as a function of temperature A flow loop was built to calibrate the sensor by passing either air or ethylene glycol over it at velocities of up to 4.4 m/s. A series of 1 to 6 min long voltage pulses were applied to the heater, increasing its temperature by approximately 5°-10°C each time, before letting it cool. The surface temperature cooling rate was recorded by the surface thermocouple. A calibration curve was developed of fluid velocities as a function of time constants for cooling of the sensor.
546
$a
English
590
$a
School code: 0779
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Industrial engineering.
$3
526216
650
4
$a
Fluid mechanics.
$3
528155
653
$a
Fluid velocity measurement
653
$a
Surface sensors
653
$a
Thermal sprayed sensor
653
$a
Velocity sensors
653
$a
Nichrome
690
$a
0548
690
$a
0204
690
$a
0546
710
2
$a
University of Toronto (Canada).
$b
Mechanical and Industrial Engineering.
$e
degree granting institution.
$3
3819498
720
1
$a
Chandra, Sanjeev
$e
degree supervisor.
773
0
$t
Masters Abstracts International
$g
86-05.
790
$a
0779
791
$a
M.A.S.
792
$a
2024
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31559346
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9534371
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入
(1)帳號:一般為「身分證號」;外籍生或交換生則為「學號」。 (2)密碼:預設為帳號末四碼。
帳號
.
密碼
.
請在此電腦上記得個人資料
取消
忘記密碼? (請注意!您必須已在系統登記E-mail信箱方能使用。)