Dynamic Single and Multi-Sequence Ca...
~
Goes, Jacob Paul,
FindBook
Google Book
Amazon
博客來
Dynamic Single and Multi-Sequence Cardiac Magnetic Resonance Acquisition and Characterization /
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Dynamic Single and Multi-Sequence Cardiac Magnetic Resonance Acquisition and Characterization // Jacob Paul Goes.
作者:
Goes, Jacob Paul,
面頁冊數:
1 electronic resource (114 pages)
附註:
Source: Dissertations Abstracts International, Volume: 86-11, Section: B.
Contained By:
Dissertations Abstracts International86-11B.
標題:
Biomedical engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=32040501
ISBN:
9798315731672
Dynamic Single and Multi-Sequence Cardiac Magnetic Resonance Acquisition and Characterization /
Goes, Jacob Paul,
Dynamic Single and Multi-Sequence Cardiac Magnetic Resonance Acquisition and Characterization /
Jacob Paul Goes. - 1 electronic resource (114 pages)
Source: Dissertations Abstracts International, Volume: 86-11, Section: B.
Cardiac Magnetic Resonance (CMR) provides a versatile tool in the clinical diagnosis and treatment recommendations for cardiac disease and dysfunction. CMR provides a noninvasive imaging modality that does not expose the patient to ionizing radiation, which is important for chronic diseases that require repeatable diagnostic screening. CMR has a variety of techniques that can provide both anatomical and functional information of clinical value and is a key area of interest for development towards better cardiac medicine.In order to be implemented in the clinical setting, a novel technique requires a robust study design in order to confirm the accuracy and precision of the candidate Magnetic Resonance (MR) biomarker. However, there is not always a suitable "gold standard" model to compare a novel technique to. One solution is to utilize known or expected dynamic response in the formation of a hypothesis. Dynamic response dependent study designs can include execution of a single experiment under unique conditions to acquire the dynamic response of a tissue model or exploiting the expected dynamic properties of a cine dataset for training a Deep Neural Network (DNN) on an imperfect dataset with noise and artifacts.Both qualitative and quantitative measures for the analysis of images are used in CMR. Quantitative measurements are more desirable than qualitative interpretation with less subjectivity, but quantitative techniques are often more complex and time consuming. For example, an experienced reader typically examines regional wall motion qualitatively. Strain imaging can produce quantitative, objective results for wall motion abnormality, and such assessment has been theorized to precede visual evidence. With recent advances to strain-encoded CMR (SENC), acquisitions can be performed in a comparable amount of time to standard Cine technique with sufficient temporal resolution without artifacts from respiratory motion or arrythmias. In this thesis, dynamic changes in strain between resting and dobutamine-induced stress will be assessed to determine if they precede invariant qualitative visual wall thickening from cine images.Magnetic Resonance Imaging (MRI) has seen less prolific implementation for several implementations due to its inherent length, which disproportionally affects CMR due to cardiac and respiratory motion. Inadequate control or correction of motion results in artifacts that compromise image quality and render non-diagnostic images. A common technique for this is the use of a directed breath-hold (BH), as this eliminates artifacts from respiratory motion. However, people who are referred for CMR may have comorbidities that may render them incapable of a BH for the required duration of a scan. Each acquisition is typically acquired under separate BHs, which requires geometric registration in order to account for inter-BH variance. Various techniques have been developed to reduce scan duration. Pre-scan calibrations are time-consuming but rarely considered for scan time reduction due to conventional single-acquisition per BH. Some pulse sequence families are more robust against certain pre-scan calibration errors than others. In this thesis, we propose a method that bypasses time-consuming pre-scans and implements a multi-acquisition single-BH Balanced Steady State Free Precession (bSSFP) Cine and Spoiled Gradient (SPGR) Tag by bypassing select pre-scans.
English
ISBN: 9798315731672Subjects--Topical Terms:
535387
Biomedical engineering.
Subjects--Index Terms:
Cardiac Magnetic Resonance
Dynamic Single and Multi-Sequence Cardiac Magnetic Resonance Acquisition and Characterization /
LDR
:04925nmm a22004333i 4500
001
2434904
005
20251001062552.5
006
m o d
007
cr|nu||||||||
008
261011s2025 miu||||||m |||||||eng d
020
$a
9798315731672
035
$a
(MiAaPQD)AAI32040501
035
$a
AAI32040501
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Goes, Jacob Paul,
$e
author.
$3
3825048
245
1 0
$a
Dynamic Single and Multi-Sequence Cardiac Magnetic Resonance Acquisition and Characterization /
$c
Jacob Paul Goes.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2025
300
$a
1 electronic resource (114 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 86-11, Section: B.
500
$a
Advisors: Kawaji, Keigo Committee members: Papavasiliou, Georgia; Arfanakis, Konstantinos; Cinar, Ali.
502
$b
Ph.D.
$c
Illinois Institute of Technology
$d
2025.
520
$a
Cardiac Magnetic Resonance (CMR) provides a versatile tool in the clinical diagnosis and treatment recommendations for cardiac disease and dysfunction. CMR provides a noninvasive imaging modality that does not expose the patient to ionizing radiation, which is important for chronic diseases that require repeatable diagnostic screening. CMR has a variety of techniques that can provide both anatomical and functional information of clinical value and is a key area of interest for development towards better cardiac medicine.In order to be implemented in the clinical setting, a novel technique requires a robust study design in order to confirm the accuracy and precision of the candidate Magnetic Resonance (MR) biomarker. However, there is not always a suitable "gold standard" model to compare a novel technique to. One solution is to utilize known or expected dynamic response in the formation of a hypothesis. Dynamic response dependent study designs can include execution of a single experiment under unique conditions to acquire the dynamic response of a tissue model or exploiting the expected dynamic properties of a cine dataset for training a Deep Neural Network (DNN) on an imperfect dataset with noise and artifacts.Both qualitative and quantitative measures for the analysis of images are used in CMR. Quantitative measurements are more desirable than qualitative interpretation with less subjectivity, but quantitative techniques are often more complex and time consuming. For example, an experienced reader typically examines regional wall motion qualitatively. Strain imaging can produce quantitative, objective results for wall motion abnormality, and such assessment has been theorized to precede visual evidence. With recent advances to strain-encoded CMR (SENC), acquisitions can be performed in a comparable amount of time to standard Cine technique with sufficient temporal resolution without artifacts from respiratory motion or arrythmias. In this thesis, dynamic changes in strain between resting and dobutamine-induced stress will be assessed to determine if they precede invariant qualitative visual wall thickening from cine images.Magnetic Resonance Imaging (MRI) has seen less prolific implementation for several implementations due to its inherent length, which disproportionally affects CMR due to cardiac and respiratory motion. Inadequate control or correction of motion results in artifacts that compromise image quality and render non-diagnostic images. A common technique for this is the use of a directed breath-hold (BH), as this eliminates artifacts from respiratory motion. However, people who are referred for CMR may have comorbidities that may render them incapable of a BH for the required duration of a scan. Each acquisition is typically acquired under separate BHs, which requires geometric registration in order to account for inter-BH variance. Various techniques have been developed to reduce scan duration. Pre-scan calibrations are time-consuming but rarely considered for scan time reduction due to conventional single-acquisition per BH. Some pulse sequence families are more robust against certain pre-scan calibration errors than others. In this thesis, we propose a method that bypasses time-consuming pre-scans and implements a multi-acquisition single-BH Balanced Steady State Free Precession (bSSFP) Cine and Spoiled Gradient (SPGR) Tag by bypassing select pre-scans.
546
$a
English
590
$a
School code: 0091
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Medical imaging.
$3
3172799
650
4
$a
Medicine.
$3
641104
650
4
$a
Bioengineering.
$3
657580
653
$a
Cardiac Magnetic Resonance
653
$a
Magnetic resonance imaging
653
$a
Pre-scan calibration
653
$a
Deep Neural Network
690
$a
0541
690
$a
0574
690
$a
0202
690
$a
0564
710
2
$a
Illinois Institute of Technology.
$b
Biomedical Engineering.
$e
degree granting institution.
$3
3825007
720
1
$a
Kawaji, Keigo
$e
degree supervisor.
773
0
$t
Dissertations Abstracts International
$g
86-11B.
790
$a
0091
791
$a
Ph.D.
792
$a
2025
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=32040501
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9530599
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入
(1)帳號:一般為「身分證號」;外籍生或交換生則為「學號」。 (2)密碼:預設為帳號末四碼。
帳號
.
密碼
.
請在此電腦上記得個人資料
取消
忘記密碼? (請注意!您必須已在系統登記E-mail信箱方能使用。)