語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
到查詢結果
[ null ]
切換:
標籤
|
MARC模式
|
ISBD
Performance of Ordinary C-Shaped Rei...
~
Unal, Mehmet Emre,
FindBook
Google Book
Amazon
博客來
Performance of Ordinary C-Shaped Reinforced Concrete Structural Walls Subjected to Wind and Seismic Loading Protocols /
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Performance of Ordinary C-Shaped Reinforced Concrete Structural Walls Subjected to Wind and Seismic Loading Protocols // Mehmet Emre Unal.
作者:
Unal, Mehmet Emre,
面頁冊數:
1 electronic resource (395 pages)
附註:
Source: Dissertations Abstracts International, Volume: 86-03, Section: B.
Contained By:
Dissertations Abstracts International86-03B.
標題:
Computer science. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31561590
ISBN:
9798384092056
Performance of Ordinary C-Shaped Reinforced Concrete Structural Walls Subjected to Wind and Seismic Loading Protocols /
Unal, Mehmet Emre,
Performance of Ordinary C-Shaped Reinforced Concrete Structural Walls Subjected to Wind and Seismic Loading Protocols /
Mehmet Emre Unal. - 1 electronic resource (395 pages)
Source: Dissertations Abstracts International, Volume: 86-03, Section: B.
The design of buildings under wind demands has traditionally been based on prescriptive code provisions such as ASCE/SEI 7, which requires the building components to stay essentially linear elastic. Recent developments in wind tunnel testing, structural analysis techniques, and performance-based design procedures led to the publication of the ASCE/SEI Prestandard for Performance-Based Wind Design (ASCE/SEI, 2019). The Prestandard allows limited inelastic behavior in ductile elements of a building's Main Wind Force Resisting System (MWFRS) under extreme wind events. However, because yielding of some building components has not historically been permitted, there is limited research available to understand the inelastic behavior of structural elements subjected to wind demands. The advantages of the performance-based wind design (PBWD) are considered to be most impactful for the design of tall buildings, where it is very common to use coupled reinforced concrete shear wall systems as the MWFRS. Although some research has been conducted to understand the inelastic behavior of reinforced concrete and steel-reinforced concrete coupling beams, there is no published research that investigates the inelastic behavior of reinforced concrete shear walls under wind demands. To fill this gap, four reinforced concrete C-shaped structural walls have been tested in two phases under quasi-static, biaxial cyclic loading protocols simulating extreme wind events. Following the wind loading protocol, a seismic loading protocol was applied.The design of the walls was based on the core-wall design of actual buildings that were designed and constructed in high-wind and low-seismic zones in the United States. The 5 in. thick flanges and webs of the walls were 30 in. and 75 in. long, respectively, representing approximately one-third scaled C-shaped walls of the core-walls of these buildings. The test walls were detailed as Ordinary walls based on the provisions of Chapter 11 of ACI 318-19. The test variable for the Phase-I walls (CW-1 and CW-2) was the longitudinal reinforcement ratio (ρl); 0.75% for CW-1 and 1.5% for CW-2. Based on the experimental results of the Phase-I walls and feedback from a Project Advisory Committee (PAC), two more walls (CW-3 and CW-4) were tested during Phase-II. The design of Phase-II walls was based on CW-2 (ρl=1.5%), and the test variables were the amount of confinement provided at the end zones of the flanges (flange edges) and the amount of axial load applied during the biaxial wind loading protocol. The wind test results indicated that for the wall with the low-to-moderate reinforcement ratio (CW-1, ρl=0.75%), rotational ductility demands of 3.0 can be achieved without any damage (e.g., concrete spalling, bar buckling, or bar fracture) and with very small residual flexural crack widths (around 0.1 mm). Since CW-1 failed at a rotational ductility demand of 20 during the seismic loading protocol, modest inelastic response can be allowed during extreme wind events for the walls with 0.75% or lower longitudinal reinforcement ratios. Concrete spalling was observed at the flange-web corners and the flange edges during the wind loading protocol for the walls with the higher longitudinal reinforcement ratio (1.5%). Depending on the amount of axial load applied during the biaxial load application, concrete crushing and bar buckling were also observed. Phase-II tests showed that the flange edges were more susceptible to damage than the other portions of the C-shaped walls. With moderate confinement provided at the flange edges and reduction in wall axial load during the biaxial loading (when the flange edges were under compression), bar buckling and concrete crushing were not observed during the wind loading protocols. Application of the seismic loading protocol revealed that, for the walls that did not sustain any significant damage during the wind tests, rotational ductility demands of at least 8.5 could be achieved prior to 20% loss in lateral strength.
English
ISBN: 9798384092056Subjects--Topical Terms:
523869
Computer science.
Subjects--Index Terms:
Performance based wind design
Performance of Ordinary C-Shaped Reinforced Concrete Structural Walls Subjected to Wind and Seismic Loading Protocols /
LDR
:05586nmm a22004453i 4500
001
2434175
005
20250912100608.5
006
m o d
007
cr|nu||||||||
008
261011s2024 miu||||||m |||||||eng d
020
$a
9798384092056
035
$a
(MiAaPQD)AAI31561590
035
$a
AAI31561590
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Unal, Mehmet Emre,
$e
author.
$3
3824069
245
1 0
$a
Performance of Ordinary C-Shaped Reinforced Concrete Structural Walls Subjected to Wind and Seismic Loading Protocols /
$c
Mehmet Emre Unal.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2024
300
$a
1 electronic resource (395 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 86-03, Section: B.
500
$a
Advisors: Wallace, John Wright Committee members: Burton, Henry J.; Kolozvari, Kristijan; Sabol, Thomas A.
502
$b
Ph.D.
$c
University of California, Los Angeles
$d
2024.
520
$a
The design of buildings under wind demands has traditionally been based on prescriptive code provisions such as ASCE/SEI 7, which requires the building components to stay essentially linear elastic. Recent developments in wind tunnel testing, structural analysis techniques, and performance-based design procedures led to the publication of the ASCE/SEI Prestandard for Performance-Based Wind Design (ASCE/SEI, 2019). The Prestandard allows limited inelastic behavior in ductile elements of a building's Main Wind Force Resisting System (MWFRS) under extreme wind events. However, because yielding of some building components has not historically been permitted, there is limited research available to understand the inelastic behavior of structural elements subjected to wind demands. The advantages of the performance-based wind design (PBWD) are considered to be most impactful for the design of tall buildings, where it is very common to use coupled reinforced concrete shear wall systems as the MWFRS. Although some research has been conducted to understand the inelastic behavior of reinforced concrete and steel-reinforced concrete coupling beams, there is no published research that investigates the inelastic behavior of reinforced concrete shear walls under wind demands. To fill this gap, four reinforced concrete C-shaped structural walls have been tested in two phases under quasi-static, biaxial cyclic loading protocols simulating extreme wind events. Following the wind loading protocol, a seismic loading protocol was applied.The design of the walls was based on the core-wall design of actual buildings that were designed and constructed in high-wind and low-seismic zones in the United States. The 5 in. thick flanges and webs of the walls were 30 in. and 75 in. long, respectively, representing approximately one-third scaled C-shaped walls of the core-walls of these buildings. The test walls were detailed as Ordinary walls based on the provisions of Chapter 11 of ACI 318-19. The test variable for the Phase-I walls (CW-1 and CW-2) was the longitudinal reinforcement ratio (ρl); 0.75% for CW-1 and 1.5% for CW-2. Based on the experimental results of the Phase-I walls and feedback from a Project Advisory Committee (PAC), two more walls (CW-3 and CW-4) were tested during Phase-II. The design of Phase-II walls was based on CW-2 (ρl=1.5%), and the test variables were the amount of confinement provided at the end zones of the flanges (flange edges) and the amount of axial load applied during the biaxial wind loading protocol. The wind test results indicated that for the wall with the low-to-moderate reinforcement ratio (CW-1, ρl=0.75%), rotational ductility demands of 3.0 can be achieved without any damage (e.g., concrete spalling, bar buckling, or bar fracture) and with very small residual flexural crack widths (around 0.1 mm). Since CW-1 failed at a rotational ductility demand of 20 during the seismic loading protocol, modest inelastic response can be allowed during extreme wind events for the walls with 0.75% or lower longitudinal reinforcement ratios. Concrete spalling was observed at the flange-web corners and the flange edges during the wind loading protocol for the walls with the higher longitudinal reinforcement ratio (1.5%). Depending on the amount of axial load applied during the biaxial load application, concrete crushing and bar buckling were also observed. Phase-II tests showed that the flange edges were more susceptible to damage than the other portions of the C-shaped walls. With moderate confinement provided at the flange edges and reduction in wall axial load during the biaxial loading (when the flange edges were under compression), bar buckling and concrete crushing were not observed during the wind loading protocols. Application of the seismic loading protocol revealed that, for the walls that did not sustain any significant damage during the wind tests, rotational ductility demands of at least 8.5 could be achieved prior to 20% loss in lateral strength.
546
$a
English
590
$a
School code: 0031
650
4
$a
Computer science.
$3
523869
650
4
$a
Architectural engineering.
$3
3174102
650
4
$a
Mechanical engineering.
$3
649730
653
$a
Performance based wind design
653
$a
Reinforced concrete
653
$a
Structural engineering
653
$a
Structural walls
653
$a
Testing
690
$a
0543
690
$a
0984
690
$a
0548
690
$a
0462
710
2
$a
University of California, Los Angeles.
$b
Civil and Environmental Engineering 0300.
$e
degree granting institution.
$3
3821458
720
1
$a
Wallace, John Wright
$e
degree supervisor.
773
0
$t
Dissertations Abstracts International
$g
86-03B.
790
$a
0031
791
$a
Ph.D.
792
$a
2024
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31561590
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9529870
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入
(1)帳號:一般為「身分證號」;外籍生或交換生則為「學號」。 (2)密碼:預設為帳號末四碼。
帳號
.
密碼
.
請在此電腦上記得個人資料
取消
忘記密碼? (請注意!您必須已在系統登記E-mail信箱方能使用。)