語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
到查詢結果
[ null ]
切換:
標籤
|
MARC模式
|
ISBD
Moss and Air: Biofiltration and Moss...
~
Pepi, William Matthew,
FindBook
Google Book
Amazon
博客來
Moss and Air: Biofiltration and Moss as a Fresh Air Generator /
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Moss and Air: Biofiltration and Moss as a Fresh Air Generator // William Matthew Pepi.
作者:
Pepi, William Matthew,
面頁冊數:
1 electronic resource (291 pages)
附註:
Source: Dissertations Abstracts International, Volume: 86-04, Section: B.
Contained By:
Dissertations Abstracts International86-04B.
標題:
Architectural engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31483174
ISBN:
9798384466444
Moss and Air: Biofiltration and Moss as a Fresh Air Generator /
Pepi, William Matthew,
Moss and Air: Biofiltration and Moss as a Fresh Air Generator /
William Matthew Pepi. - 1 electronic resource (291 pages)
Source: Dissertations Abstracts International, Volume: 86-04, Section: B.
This thesis addresses both indoor air quality (IAQ), the top environmental risk to human health, and building energy consumption, a principal driver of climate change. Plants can enhance both IAQ and building energy efficiency. Botanical biofilters host microbial populations that remediate a diversity of contaminants while plant photosynthesis may provide CO2-O2 balance of occupant respiration, enabling continuous clean air recirculation and HVAC energy savings - by reducing the supply and conditioning of outdoor air. In other words, beyond hosting microbial biofiltration, plants may be complete fresh air generators. Vascular botanical biofilters (state of the art) are a promising nascent technology; facing challenges regarding system size, grow light energy, CO2 assimilation, airflow, and root-zone drying, which can inhibit microbial bioremediation. Vascular biofilters show high VOC removal but insufficient evidence for photosynthetic CO2 assimilation of occupant respiration. Thus, current systems effectively remove VOCs but do not fully regenerate fresh air. This dissertation argues that moss biofiltration is a feasible alternative avenue towards complete indoor fresh air generation. We posit that moss - with its fractal structure, high surface area, porosity, water content, robust microbiotic consortia, mat-like morphology, and high chloroplast efficiency - can facilitate uniform air flux, rapid contaminant mass transfer, and high photosynthetic carbon assimilation in a compact and energy-efficient package. In addition to its (known) filtration efficacy, we hypothesize that moss photosynthesis occurs rapidly under high air flux and CO2 concentrations, potentially allowing for complete indoor air recirculation and resolution of energy-IAQ tradeoffs. We deploy three distinct methodologies. (1) A mini meta-analysis synthesizes botanical biofiltration studies into normalized metrics, such as filtration efficiency and clean air delivery rate, enabling quantitative comparisons with state-of-the-art systems. (2) Empirical experiments on moss biofilter prototypes investigate carbon assimilation at high air flux and CO2 concentrations, VOC and PM filter efficiencies, and evapotranspiration (moss's cooling effect). Additionally, in vitro tests characterize dose-response inhibition of fungal and microbial activity by moss metabolites. (3) We present a parametric modeling framework that co-simulates air mass balance and building energy for arbitrary biofilter and building systems, enabling estimation of air quality and total energy consumption. We run a suite of modeling studies (over 30,000 individual variants) investigating the impact of climate, occupancy, metabolic rate, HVAC system types, biofiltration systems, future weather, and other parameters. (1) The statistical review of botanical biofiltration research highlights the field's incipient nature. Besides important parameters like airflow rate, the study itself significantly predicts biofilter efficiency, indicating varied experimental parameters and biofilter systems can yield diverse results. (2) Although typically observed to be low-light slow-growers, we observed that under high airflow (approx. > 3 m/s), light (PPFD > 250 µmol/m2/s) and CO2 (approx. > 1000 ppm), moss biofilter photosynthesis outperforms vascular systems (CADRCO2 > 0.5 m3air/m2moss/hr), in a package about ten times smaller (per person) and using a third of the light energy. Thus, moss photosynthesis may typically be limited by environmental parameters, not intrinsic physiology. (3) Our simulations reveal that biofiltration in general surpasses conventional methods for improving IAQ such as (abiotic) filtration and outdoor air dilution; and, in some cases, can resolve energy-IAQ tradeoffs. The indoor-to-outdoor temperature differential is the best predictor of energy savings, with extreme climates benefiting most from indoor air recirculation. Overall and in a detailed multizone energy-air-quality model, moss systems outperform vascular biofilters on net energy use intensity, air quality, and return on investment metrics. We thus provide some evidence that moss is an attractive platform for achieving complete and regenerative indoor air recirculation.
English
ISBN: 9798384466444Subjects--Topical Terms:
3174102
Architectural engineering.
Subjects--Index Terms:
Biofiltration
Moss and Air: Biofiltration and Moss as a Fresh Air Generator /
LDR
:05790nmm a22004573i 4500
001
2432549
005
20250718090828.5
006
m o d
007
cr|nu||||||||
008
261011s2024 miu||||||m |||||||eng d
020
$a
9798384466444
035
$a
(MiAaPQD)AAI31483174
035
$a
AAI31483174
040
$a
MiAaPQD
$b
eng
$c
MiAaPQD
$e
rda
100
1
$a
Pepi, William Matthew,
$e
author.
$3
3821819
245
1 0
$a
Moss and Air: Biofiltration and Moss as a Fresh Air Generator /
$c
William Matthew Pepi.
264
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2024
300
$a
1 electronic resource (291 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 86-04, Section: B.
500
$a
Advisors: Karlicek, Robert; Tsamis, Alexandros Committee members: Shelden, Dennis; Kar, Kushick; Draper, Joshua.
502
$b
Ph.D.
$c
Rensselaer Polytechnic Institute
$d
2024.
520
$a
This thesis addresses both indoor air quality (IAQ), the top environmental risk to human health, and building energy consumption, a principal driver of climate change. Plants can enhance both IAQ and building energy efficiency. Botanical biofilters host microbial populations that remediate a diversity of contaminants while plant photosynthesis may provide CO2-O2 balance of occupant respiration, enabling continuous clean air recirculation and HVAC energy savings - by reducing the supply and conditioning of outdoor air. In other words, beyond hosting microbial biofiltration, plants may be complete fresh air generators. Vascular botanical biofilters (state of the art) are a promising nascent technology; facing challenges regarding system size, grow light energy, CO2 assimilation, airflow, and root-zone drying, which can inhibit microbial bioremediation. Vascular biofilters show high VOC removal but insufficient evidence for photosynthetic CO2 assimilation of occupant respiration. Thus, current systems effectively remove VOCs but do not fully regenerate fresh air. This dissertation argues that moss biofiltration is a feasible alternative avenue towards complete indoor fresh air generation. We posit that moss - with its fractal structure, high surface area, porosity, water content, robust microbiotic consortia, mat-like morphology, and high chloroplast efficiency - can facilitate uniform air flux, rapid contaminant mass transfer, and high photosynthetic carbon assimilation in a compact and energy-efficient package. In addition to its (known) filtration efficacy, we hypothesize that moss photosynthesis occurs rapidly under high air flux and CO2 concentrations, potentially allowing for complete indoor air recirculation and resolution of energy-IAQ tradeoffs. We deploy three distinct methodologies. (1) A mini meta-analysis synthesizes botanical biofiltration studies into normalized metrics, such as filtration efficiency and clean air delivery rate, enabling quantitative comparisons with state-of-the-art systems. (2) Empirical experiments on moss biofilter prototypes investigate carbon assimilation at high air flux and CO2 concentrations, VOC and PM filter efficiencies, and evapotranspiration (moss's cooling effect). Additionally, in vitro tests characterize dose-response inhibition of fungal and microbial activity by moss metabolites. (3) We present a parametric modeling framework that co-simulates air mass balance and building energy for arbitrary biofilter and building systems, enabling estimation of air quality and total energy consumption. We run a suite of modeling studies (over 30,000 individual variants) investigating the impact of climate, occupancy, metabolic rate, HVAC system types, biofiltration systems, future weather, and other parameters. (1) The statistical review of botanical biofiltration research highlights the field's incipient nature. Besides important parameters like airflow rate, the study itself significantly predicts biofilter efficiency, indicating varied experimental parameters and biofilter systems can yield diverse results. (2) Although typically observed to be low-light slow-growers, we observed that under high airflow (approx. > 3 m/s), light (PPFD > 250 µmol/m2/s) and CO2 (approx. > 1000 ppm), moss biofilter photosynthesis outperforms vascular systems (CADRCO2 > 0.5 m3air/m2moss/hr), in a package about ten times smaller (per person) and using a third of the light energy. Thus, moss photosynthesis may typically be limited by environmental parameters, not intrinsic physiology. (3) Our simulations reveal that biofiltration in general surpasses conventional methods for improving IAQ such as (abiotic) filtration and outdoor air dilution; and, in some cases, can resolve energy-IAQ tradeoffs. The indoor-to-outdoor temperature differential is the best predictor of energy savings, with extreme climates benefiting most from indoor air recirculation. Overall and in a detailed multizone energy-air-quality model, moss systems outperform vascular biofilters on net energy use intensity, air quality, and return on investment metrics. We thus provide some evidence that moss is an attractive platform for achieving complete and regenerative indoor air recirculation.
546
$a
English
590
$a
School code: 0185
650
4
$a
Architectural engineering.
$3
3174102
650
4
$a
Plant sciences.
$3
3173832
650
4
$a
Systems science.
$3
3168411
653
$a
Biofiltration
653
$a
HVAC energy efficiency
653
$a
Indoor air quality
653
$a
Moss
653
$a
Phytoremediation
653
$a
Ventilation
690
$a
0462
690
$a
0479
690
$a
0790
710
2
$a
Rensselaer Polytechnic Institute.
$b
Architecture.
$e
degree granting institution.
$3
3821820
720
1
$a
Karlicek, Robert
$e
degree supervisor.
720
1
$a
Tsamis, Alexandros
$e
degree supervisor.
773
0
$t
Dissertations Abstracts International
$g
86-04B.
790
$a
0185
791
$a
Ph.D.
792
$a
2024
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=31483174
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9528244
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入
(1)帳號:一般為「身分證號」;外籍生或交換生則為「學號」。 (2)密碼:預設為帳號末四碼。
帳號
.
密碼
.
請在此電腦上記得個人資料
取消
忘記密碼? (請注意!您必須已在系統登記E-mail信箱方能使用。)