語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
到查詢結果
[ null ]
切換:
標籤
|
MARC模式
|
ISBD
A Short-Wavelength Infrared Photon D...
~
Fathipour, Vala.
FindBook
Google Book
Amazon
博客來
A Short-Wavelength Infrared Photon Detector Based on Charge Injection.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
A Short-Wavelength Infrared Photon Detector Based on Charge Injection./
作者:
Fathipour, Vala.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2016,
面頁冊數:
231 p.
附註:
Source: Dissertations Abstracts International, Volume: 78-06, Section: B.
Contained By:
Dissertations Abstracts International78-06B.
標題:
Engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10195673
ISBN:
9781369448092
A Short-Wavelength Infrared Photon Detector Based on Charge Injection.
Fathipour, Vala.
A Short-Wavelength Infrared Photon Detector Based on Charge Injection.
- Ann Arbor : ProQuest Dissertations & Theses, 2016 - 231 p.
Source: Dissertations Abstracts International, Volume: 78-06, Section: B.
Thesis (Ph.D.)--Northwestern University, 2016.
.
Unfortunately, after decades of research, the existing technology candidates in the short-wave infrared (SWIR) band still suffer from inherent limitations, such as low quantum efficiency, high noise levels, or requirement of extremely low temperatures. To solve these problems, we have developed an electron-injection technique, based on the single-photon detection of the rod cells. This detection mechanism can provide both high efficiency and high sensitivity at room temperature, a condition that is very difficult to achieve in conventional SWIR detectors. Electron-injection (EI) detector offers an overall system-level sensitivity enhancement due to a feedback stabilized internal avalanche-free gain. The amplification method is inherently low noise, and devices exhibit an excess noise of unity. The detector operates in linear-mode and requires bias voltage of a few volts. It is based on the mature InP material system and has a cutoff wavelength of 1700 nm. EI detectors operate by absorbing photons in a large volume, confining the photo-excited holes into a small sensor, and then amplifying the signal through electron-injection. EI detectors have been designed, fabricated, and tested during two generations of development and optimization cycles. The shortcomings of the first-generation devices were addressed in the second-generation detectors. Second-generation devices achieved high gain, high bandwidth, and low leakage current in a single structure at room temperature. Measurement on devices with an injector diameter of 10 μm and an absorber diameter of 30 μm showed high-speed response ~ 6 ns rise time, low jitter ~12 ps, high amplification of more than 1000 (at optical power levels larger than few nW), unity excess noise factor, low leakage current (amplified dark current ~10 nA), at bias voltage of -3 V, and at room temperature. Second-generation devices achieved two orders of magnitude reduction in the dark current and four orders of magnitude improvement in bandwidth compared with first-generation devices. The dark current density of the second-generation EI detector outperforms the state-of-the-art technology, the SWIR HgCdTe eAPD by more than an order of magnitude at all measured temperatures, from 300 K down to 160 K. A performance comparison with other SWIR detector technologies with internal amplification (including phototransistors and avalanche photodiodes) in terms of signal-to-noise ratio at low light level is demonstrated. Comprehensive analytical and simulation models are developed for the first time for the design and optimization of the electron-injection detectors and similar heterojunction phototransistors. Using these models, we illustrate the benefit of scaling of the injector diameter with respect to the trapping/absorbing layer diameter and confirm it by measurement results. The improvements in the second-generation devices have opened up applications for these detectors in medical field (optical coherence tomography), remote sensing (light detection and ranging), and astronomy (exoplanet detection). We demonstrated that the utilization of EI detectors in optical coherence tomography (OCT) greatly enhances system performance. The limitations of existing OCT photon detectors, including the nanowire single-photon detectors, have prevented achieving shot-noise-limit of sensing without using balanced detection scheme in swept source OCT (SS-OCT). Unfortunately balanced detection scheme increases OCT system size and cost as it adds complexity and requires additional components compared to a single detector operation. Using the electron-injection detector, we show for the first time achievement of the shot noise limited performance without using the balanced detection technique. Our system is significantly simpler, and can achieve the shot-noise-limited sensitivity of ~ −105 dB at more than 30 times lower reference laser power as the best-reported balanced detector results. As such, EI detectors allow weak light sources to be used for imaging weakly reflecting samples and can immediately address the demand for high-speed portable OCT imaging systems. Finally we investigated utilization of EI detectors in a Light Detection and Ranging (LiDAR) system. Among the different components of a LiDAR receiver system, the optical detector directly affects the instrument sensitivity performance. The EI detectors' characteristics including the high gain, the unity excess noise, the good timing resolution, and the low bias voltage requirement, suggest that they are a good candidate for high-resolution flash LiDAR applications with millimeter scale depth resolution at longer ranges compared with p-i-n diodes. Based on our experimentally measured device characteristics, we compare the performance of the electron-injection detector with commercially available linear-mode InGaAs APD as well as a p-i-n diode using a theoretical model. Flash LiDAR images obtained by our model, show the electron-injection detector array achieves better resolution with higher signal-to-noise compared with both the InGaAs APD and the p-i-n array (of 100 x 100 element). We have designed a laboratory set up, with receiver optics aperture diameter of 3 mm that allows an EI detector (with 30 μm absorber diameter) to be used for LiDAR imaging with sub centimeter resolution. (Abstract shortened by ProQuest.).
ISBN: 9781369448092Subjects--Topical Terms:
586835
Engineering.
Subjects--Index Terms:
Electron-injection detector
A Short-Wavelength Infrared Photon Detector Based on Charge Injection.
LDR
:06710nmm a2200433 4500
001
2399832
005
20240916065954.5
006
m o d
007
cr#unu||||||||
008
251215s2016 ||||||||||||||||| ||eng d
020
$a
9781369448092
035
$a
(MiAaPQ)AAI10195673
035
$a
(MiAaPQ)northwestern:13484
035
$a
AAI10195673
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Fathipour, Vala.
$3
3769807
245
1 2
$a
A Short-Wavelength Infrared Photon Detector Based on Charge Injection.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2016
300
$a
231 p.
500
$a
Source: Dissertations Abstracts International, Volume: 78-06, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Mohseni, Hooman.
502
$a
Thesis (Ph.D.)--Northwestern University, 2016.
506
$a
.
520
$a
Unfortunately, after decades of research, the existing technology candidates in the short-wave infrared (SWIR) band still suffer from inherent limitations, such as low quantum efficiency, high noise levels, or requirement of extremely low temperatures. To solve these problems, we have developed an electron-injection technique, based on the single-photon detection of the rod cells. This detection mechanism can provide both high efficiency and high sensitivity at room temperature, a condition that is very difficult to achieve in conventional SWIR detectors. Electron-injection (EI) detector offers an overall system-level sensitivity enhancement due to a feedback stabilized internal avalanche-free gain. The amplification method is inherently low noise, and devices exhibit an excess noise of unity. The detector operates in linear-mode and requires bias voltage of a few volts. It is based on the mature InP material system and has a cutoff wavelength of 1700 nm. EI detectors operate by absorbing photons in a large volume, confining the photo-excited holes into a small sensor, and then amplifying the signal through electron-injection. EI detectors have been designed, fabricated, and tested during two generations of development and optimization cycles. The shortcomings of the first-generation devices were addressed in the second-generation detectors. Second-generation devices achieved high gain, high bandwidth, and low leakage current in a single structure at room temperature. Measurement on devices with an injector diameter of 10 μm and an absorber diameter of 30 μm showed high-speed response ~ 6 ns rise time, low jitter ~12 ps, high amplification of more than 1000 (at optical power levels larger than few nW), unity excess noise factor, low leakage current (amplified dark current ~10 nA), at bias voltage of -3 V, and at room temperature. Second-generation devices achieved two orders of magnitude reduction in the dark current and four orders of magnitude improvement in bandwidth compared with first-generation devices. The dark current density of the second-generation EI detector outperforms the state-of-the-art technology, the SWIR HgCdTe eAPD by more than an order of magnitude at all measured temperatures, from 300 K down to 160 K. A performance comparison with other SWIR detector technologies with internal amplification (including phototransistors and avalanche photodiodes) in terms of signal-to-noise ratio at low light level is demonstrated. Comprehensive analytical and simulation models are developed for the first time for the design and optimization of the electron-injection detectors and similar heterojunction phototransistors. Using these models, we illustrate the benefit of scaling of the injector diameter with respect to the trapping/absorbing layer diameter and confirm it by measurement results. The improvements in the second-generation devices have opened up applications for these detectors in medical field (optical coherence tomography), remote sensing (light detection and ranging), and astronomy (exoplanet detection). We demonstrated that the utilization of EI detectors in optical coherence tomography (OCT) greatly enhances system performance. The limitations of existing OCT photon detectors, including the nanowire single-photon detectors, have prevented achieving shot-noise-limit of sensing without using balanced detection scheme in swept source OCT (SS-OCT). Unfortunately balanced detection scheme increases OCT system size and cost as it adds complexity and requires additional components compared to a single detector operation. Using the electron-injection detector, we show for the first time achievement of the shot noise limited performance without using the balanced detection technique. Our system is significantly simpler, and can achieve the shot-noise-limited sensitivity of ~ −105 dB at more than 30 times lower reference laser power as the best-reported balanced detector results. As such, EI detectors allow weak light sources to be used for imaging weakly reflecting samples and can immediately address the demand for high-speed portable OCT imaging systems. Finally we investigated utilization of EI detectors in a Light Detection and Ranging (LiDAR) system. Among the different components of a LiDAR receiver system, the optical detector directly affects the instrument sensitivity performance. The EI detectors' characteristics including the high gain, the unity excess noise, the good timing resolution, and the low bias voltage requirement, suggest that they are a good candidate for high-resolution flash LiDAR applications with millimeter scale depth resolution at longer ranges compared with p-i-n diodes. Based on our experimentally measured device characteristics, we compare the performance of the electron-injection detector with commercially available linear-mode InGaAs APD as well as a p-i-n diode using a theoretical model. Flash LiDAR images obtained by our model, show the electron-injection detector array achieves better resolution with higher signal-to-noise compared with both the InGaAs APD and the p-i-n array (of 100 x 100 element). We have designed a laboratory set up, with receiver optics aperture diameter of 3 mm that allows an EI detector (with 30 μm absorber diameter) to be used for LiDAR imaging with sub centimeter resolution. (Abstract shortened by ProQuest.).
590
$a
School code: 0163.
650
4
$a
Engineering.
$3
586835
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Optics.
$3
517925
653
$a
Electron-injection detector
653
$a
Infrared detector
653
$a
Light detection and ranging
653
$a
Photon detector
653
$a
Phototransistor
653
$a
Short-wave infrared
690
$a
0537
690
$a
0544
690
$a
0752
710
2
$a
Northwestern University.
$b
Electrical Engineering.
$3
3285556
773
0
$t
Dissertations Abstracts International
$g
78-06B.
790
$a
0163
791
$a
Ph.D.
792
$a
2016
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10195673
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9508152
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入
(1)帳號:一般為「身分證號」;外籍生或交換生則為「學號」。 (2)密碼:預設為帳號末四碼。
帳號
.
密碼
.
請在此電腦上記得個人資料
取消
忘記密碼? (請注意!您必須已在系統登記E-mail信箱方能使用。)