Development of Multi-Stage Elastocaloric Cooling Devices.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Development of Multi-Stage Elastocaloric Cooling Devices./
作者:
Emaikwu, Nehemiah.
面頁冊數:
1 online resource (131 pages)
附註:
Source: Dissertations Abstracts International, Volume: 83-12, Section: B.
Contained By:
Dissertations Abstracts International83-12B.
標題:
Mechanical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29163182click for full text (PQDT)
ISBN:
9798834017547
Development of Multi-Stage Elastocaloric Cooling Devices.
Emaikwu, Nehemiah.
Development of Multi-Stage Elastocaloric Cooling Devices.
- 1 online resource (131 pages)
Source: Dissertations Abstracts International, Volume: 83-12, Section: B.
Thesis (Ph.D.)--University of Maryland, College Park, 2022.
Includes bibliographical references
Elastocaloric solid-state refrigerants have lower environmental impact compared to conventional vapor compression refrigerants, but they require significant advancements to gain widespread implementation. Two barriers that prevent adoption are low temperature lift and poor fatigue life. This dissertation addresses those challenges through a single, scalable architecture with the objectives of 1) designing high-performing elastocaloric devices, and 2) maximizing temperature lift. The developed prototype consists of twenty-three 17 mm long, thermally insulated Ni-Ti tubes in a staggered pattern that exchange heat with the surrounding fluid medium through their external surface areas. They are contained inside a 3D-printed plastic that provides alignment and restricts heat transfer to other components. A top loader and fixed bottom plate transfer compressive loads to the tubes, and a 3D-printed housing encapsulates all components. Single, two, and three-stage configurations were experimentally investigated. A sensitivity analysis was conducted on the single-stage device and identified fluid-solid ratio, loading/unloading time, and strain as three parameters that could increase temperature span by over 1.5 K each. The combination of these findings resulted in a maximum steady-state temperature span of 16.6 K (9.7 K in heating and 6.8 K in cooling) at 4% strain and under zero load conditions. The temperature lift was increased in the two and three-stage configurations which achieved 20.2 K and 23.2 K, respectively, under similar operating conditions. Validated 1D numerical models developed for this work confirm that the multi-staging approach positively impacts thermal response, though with decaying significance as the number of banks increases. By further optimizing the operation condition which minimized the water volume in the fluid loop, the three-stage device was ultimately able to develop the largest lift of 27.4 K. The tubes used in the single and two-stage tests also withstood over 30,000 cycles without failure, showing promising fatigue life behavior and emphasizing the viability of this alternative cooling technology.
Electronic reproduction.
Ann Arbor, Mich. :
ProQuest,
2023
Mode of access: World Wide Web
ISBN: 9798834017547Subjects--Topical Terms:
649730
Mechanical engineering.
Subjects--Index Terms:
Elastocaloric coolingIndex Terms--Genre/Form:
542853
Electronic books.
Development of Multi-Stage Elastocaloric Cooling Devices.
LDR
:03518nmm a2200385K 4500
001
2353715
005
20230313091332.5
006
m o d
007
cr mn ---uuuuu
008
241011s2022 xx obm 000 0 eng d
020
$a
9798834017547
035
$a
(MiAaPQ)AAI29163182
035
$a
AAI29163182
040
$a
MiAaPQ
$b
eng
$c
MiAaPQ
$d
NTU
100
1
$a
Emaikwu, Nehemiah.
$3
3694045
245
1 0
$a
Development of Multi-Stage Elastocaloric Cooling Devices.
264
0
$c
2022
300
$a
1 online resource (131 pages)
336
$a
text
$b
txt
$2
rdacontent
337
$a
computer
$b
c
$2
rdamedia
338
$a
online resource
$b
cr
$2
rdacarrier
500
$a
Source: Dissertations Abstracts International, Volume: 83-12, Section: B.
500
$a
Advisor: Radermacher, Reinhard; Takeuchi, Ichiro.
502
$a
Thesis (Ph.D.)--University of Maryland, College Park, 2022.
504
$a
Includes bibliographical references
520
$a
Elastocaloric solid-state refrigerants have lower environmental impact compared to conventional vapor compression refrigerants, but they require significant advancements to gain widespread implementation. Two barriers that prevent adoption are low temperature lift and poor fatigue life. This dissertation addresses those challenges through a single, scalable architecture with the objectives of 1) designing high-performing elastocaloric devices, and 2) maximizing temperature lift. The developed prototype consists of twenty-three 17 mm long, thermally insulated Ni-Ti tubes in a staggered pattern that exchange heat with the surrounding fluid medium through their external surface areas. They are contained inside a 3D-printed plastic that provides alignment and restricts heat transfer to other components. A top loader and fixed bottom plate transfer compressive loads to the tubes, and a 3D-printed housing encapsulates all components. Single, two, and three-stage configurations were experimentally investigated. A sensitivity analysis was conducted on the single-stage device and identified fluid-solid ratio, loading/unloading time, and strain as three parameters that could increase temperature span by over 1.5 K each. The combination of these findings resulted in a maximum steady-state temperature span of 16.6 K (9.7 K in heating and 6.8 K in cooling) at 4% strain and under zero load conditions. The temperature lift was increased in the two and three-stage configurations which achieved 20.2 K and 23.2 K, respectively, under similar operating conditions. Validated 1D numerical models developed for this work confirm that the multi-staging approach positively impacts thermal response, though with decaying significance as the number of banks increases. By further optimizing the operation condition which minimized the water volume in the fluid loop, the three-stage device was ultimately able to develop the largest lift of 27.4 K. The tubes used in the single and two-stage tests also withstood over 30,000 cycles without failure, showing promising fatigue life behavior and emphasizing the viability of this alternative cooling technology.
533
$a
Electronic reproduction.
$b
Ann Arbor, Mich. :
$c
ProQuest,
$d
2023
538
$a
Mode of access: World Wide Web
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Thermodynamics.
$3
517304
650
4
$a
Materials science.
$3
543314
653
$a
Elastocaloric cooling
653
$a
Heat pump
653
$a
Shape memory alloy
653
$a
Thermoelastic
655
7
$a
Electronic books.
$2
lcsh
$3
542853
690
$a
0548
690
$a
0348
690
$a
0794
710
2
$a
ProQuest Information and Learning Co.
$3
783688
710
2
$a
University of Maryland, College Park.
$b
Mechanical Engineering.
$3
1018396
773
0
$t
Dissertations Abstracts International
$g
83-12B.
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29163182
$z
click for full text (PQDT)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9476071
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入
(1)帳號:一般為「身分證號」;外籍生或交換生則為「學號」。 (2)密碼:預設為帳號末四碼。
帳號
.
密碼
.
請在此電腦上記得個人資料
取消
忘記密碼? (請注意!您必須已在系統登記E-mail信箱方能使用。)