語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
到查詢結果
[ null ]
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
Fundamental Mechanisms of Load Transfer in the Human Vertebral Body Following Lumbar Total Disc Arthroplasty.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Fundamental Mechanisms of Load Transfer in the Human Vertebral Body Following Lumbar Total Disc Arthroplasty./
作者:
Bonnheim, Noah.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2020,
面頁冊數:
98 p.
附註:
Source: Dissertations Abstracts International, Volume: 82-05, Section: B.
Contained By:
Dissertations Abstracts International82-05B.
標題:
Biomechanics. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28090208
ISBN:
9798691237980
Fundamental Mechanisms of Load Transfer in the Human Vertebral Body Following Lumbar Total Disc Arthroplasty.
Bonnheim, Noah.
Fundamental Mechanisms of Load Transfer in the Human Vertebral Body Following Lumbar Total Disc Arthroplasty.
- Ann Arbor : ProQuest Dissertations & Theses, 2020 - 98 p.
Source: Dissertations Abstracts International, Volume: 82-05, Section: B.
Thesis (Ph.D.)--University of California, Berkeley, 2020.
This item must not be sold to any third party vendors.
The overall goal of this research is to provide insight into the bone biomechanics of human lumbar vertebrae implanted with total disc arthroplasty (TDA) implants. The research elucidates fundamental mechanisms by which lumbar TDA implants alter the yield strength of the vertebral body, stress in the bone tissue, and trabecular-cortical load-sharing behavior. The findings could have broad clinical and scientific implications related to pre-operative assessment of bone quality, in vitro test protocols for device development and regulation, the development of new implant designs, and clinical exclusion criteria. Ultimately, the hope is that this insight can be used to improve clinical outcomes for this class of device, and, in turn, contribute to the broad effort of addressing the global health burden associated with degenerative spinal pathologies.This dissertation comprises a series of computational experiments conducted on human cadaveric lumbar vertebrae using a combination of high-resolution micro-computed tomography image data with parallel linear and nonlinear finite element analysis implemented on a peta-scale supercomputing cluster. The goals of these studies are to assess mechanisms of load transfer and stress development in the bone, including how tissue-level stress depends on the loading mode of the implant, its size and material characteristics, and inter-individual variations in the structural features of the vertebral body.The primary results indicate that the load-transfer behavior in the underlying vertebral bone is substantially altered by TDA, causing high levels of trabecular bone stress, diminishing the role of the cortical shell, and substantially reducing the whole-bone yield strength. These findings were assessed in relationship to the vertebral bone's morphology and microstructure, enabling mechanistic insight into bone sub-failure and failure behavior. A key finding was that small declines in trabecular bone volume fraction can have a magnified effect on whole-bone yield strength following TDA; therefore, pre-operative assessment of bone quality should optimally focus on the trabecular centrum.Another important finding was that when the footplate of a TDA implant is loaded through its anterior or posterior rim, representing load-transfer into the bone following impingement induced by flexion or extension, bone stress near the impinged region increases substantially. This localized stress increase causes a reduction in whole-bone yield strength, suggesting that subsidence might be caused, in some cases, by impingement-type loading. Pre-clinical subsidence testing of TDA implants should therefore include some form of evaluation of bending-induced impingement if the implant enables this type of loading in vivo. As a possible strategy to help reduce the risk of implant subsidence, future research might be directed at whether an implant could be designed to reduce the frequency or strength-reduction effects of impingement loading.In closing, this dissertation elucidates fundamental mechanisms by which the vertebral bone tissue resists the loads applied by lumbar TDA implants. This mechanistic insight was used to identified possible targets-including pre-clinical tests and implant design considerations-that might help to improve clinical outcomes for this class of device.
ISBN: 9798691237980Subjects--Topical Terms:
548685
Biomechanics.
Subjects--Index Terms:
Computed tomography
Fundamental Mechanisms of Load Transfer in the Human Vertebral Body Following Lumbar Total Disc Arthroplasty.
LDR
:04817nmm a2200481 4500
001
2351837
005
20221111113652.5
008
241004s2020 ||||||||||||||||| ||eng d
020
$a
9798691237980
035
$a
(MiAaPQ)AAI28090208
035
$a
AAI28090208
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Bonnheim, Noah.
$3
3691414
245
1 0
$a
Fundamental Mechanisms of Load Transfer in the Human Vertebral Body Following Lumbar Total Disc Arthroplasty.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2020
300
$a
98 p.
500
$a
Source: Dissertations Abstracts International, Volume: 82-05, Section: B.
500
$a
Advisor: Keaveny, Tony M.;Pruitt, Lisa A.
502
$a
Thesis (Ph.D.)--University of California, Berkeley, 2020.
506
$a
This item must not be sold to any third party vendors.
520
$a
The overall goal of this research is to provide insight into the bone biomechanics of human lumbar vertebrae implanted with total disc arthroplasty (TDA) implants. The research elucidates fundamental mechanisms by which lumbar TDA implants alter the yield strength of the vertebral body, stress in the bone tissue, and trabecular-cortical load-sharing behavior. The findings could have broad clinical and scientific implications related to pre-operative assessment of bone quality, in vitro test protocols for device development and regulation, the development of new implant designs, and clinical exclusion criteria. Ultimately, the hope is that this insight can be used to improve clinical outcomes for this class of device, and, in turn, contribute to the broad effort of addressing the global health burden associated with degenerative spinal pathologies.This dissertation comprises a series of computational experiments conducted on human cadaveric lumbar vertebrae using a combination of high-resolution micro-computed tomography image data with parallel linear and nonlinear finite element analysis implemented on a peta-scale supercomputing cluster. The goals of these studies are to assess mechanisms of load transfer and stress development in the bone, including how tissue-level stress depends on the loading mode of the implant, its size and material characteristics, and inter-individual variations in the structural features of the vertebral body.The primary results indicate that the load-transfer behavior in the underlying vertebral bone is substantially altered by TDA, causing high levels of trabecular bone stress, diminishing the role of the cortical shell, and substantially reducing the whole-bone yield strength. These findings were assessed in relationship to the vertebral bone's morphology and microstructure, enabling mechanistic insight into bone sub-failure and failure behavior. A key finding was that small declines in trabecular bone volume fraction can have a magnified effect on whole-bone yield strength following TDA; therefore, pre-operative assessment of bone quality should optimally focus on the trabecular centrum.Another important finding was that when the footplate of a TDA implant is loaded through its anterior or posterior rim, representing load-transfer into the bone following impingement induced by flexion or extension, bone stress near the impinged region increases substantially. This localized stress increase causes a reduction in whole-bone yield strength, suggesting that subsidence might be caused, in some cases, by impingement-type loading. Pre-clinical subsidence testing of TDA implants should therefore include some form of evaluation of bending-induced impingement if the implant enables this type of loading in vivo. As a possible strategy to help reduce the risk of implant subsidence, future research might be directed at whether an implant could be designed to reduce the frequency or strength-reduction effects of impingement loading.In closing, this dissertation elucidates fundamental mechanisms by which the vertebral bone tissue resists the loads applied by lumbar TDA implants. This mechanistic insight was used to identified possible targets-including pre-clinical tests and implant design considerations-that might help to improve clinical outcomes for this class of device.
590
$a
School code: 0028.
650
4
$a
Biomechanics.
$3
548685
650
4
$a
Histology.
$3
641250
650
4
$a
Public health.
$3
534748
650
4
$a
Design.
$3
518875
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Health care management.
$3
2122906
650
4
$a
Morphology.
$3
591167
653
$a
Computed tomography
653
$a
Disc degeneration
653
$a
Finite element analysis
653
$a
Lumbar spine
653
$a
Total disc arthroplasty
653
$a
Total disc replacement
653
$a
In vivo
653
$a
In vitro
653
$a
Bone stress
653
$a
TDA implant
690
$a
0648
690
$a
0287
690
$a
0573
690
$a
0389
690
$a
0541
690
$a
0414
690
$a
0769
710
2
$a
University of California, Berkeley.
$b
Mechanical Engineering.
$3
1043692
773
0
$t
Dissertations Abstracts International
$g
82-05B.
790
$a
0028
791
$a
Ph.D.
792
$a
2020
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28090208
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9474275
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入
(1)帳號:一般為「身分證號」;外籍生或交換生則為「學號」。 (2)密碼:預設為帳號末四碼。
帳號
.
密碼
.
請在此電腦上記得個人資料
取消
忘記密碼? (請注意!您必須已在系統登記E-mail信箱方能使用。)