A Predictive Simulation Framework for Buoyancy-Driven Natural Ventilation in Office Buildings.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
A Predictive Simulation Framework for Buoyancy-Driven Natural Ventilation in Office Buildings./
作者:
Chen, Chen.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2022,
面頁冊數:
152 p.
附註:
Source: Dissertations Abstracts International, Volume: 84-01, Section: B.
Contained By:
Dissertations Abstracts International84-01B.
標題:
Heat transfer. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29176550
ISBN:
9798835548217
A Predictive Simulation Framework for Buoyancy-Driven Natural Ventilation in Office Buildings.
Chen, Chen.
A Predictive Simulation Framework for Buoyancy-Driven Natural Ventilation in Office Buildings.
- Ann Arbor : ProQuest Dissertations & Theses, 2022 - 152 p.
Source: Dissertations Abstracts International, Volume: 84-01, Section: B.
Thesis (Ph.D.)--Stanford University, 2022.
This item must not be sold to any third party vendors.
Natural ventilation and cooling can significantly reduce building energy consumption, but inherent variability in boundary and operating conditions makes optimal and robust design of natural ventilation a challenging task. The goal of this study is to enable robust design and operation of natural ventilation systems by developing an efficient simulation framework that can predict the building's thermal response under buoyancy-driven natural ventilation. A simplified building thermal model that solves for the time-evolution of the volume-averaged indoor air temperature with uncertain quantification (UQ) can provide an intuition of the likely effects of design choices under a variety of operating conditions in the early building design stage. Subsequently, computational fluid dynamics (CFD) simulations can be employed to fine-tune the building design at the design development stage, and the CFD results can be used to reduce the uncertainty in the building thermal model coefficients that determine the flow and heat transfer rates. The predictive capability of the resulting multi-fidelity framework was validated with a carefully designed full-scale experiment performed in an operational atrium building. A CFD-based experimental design ensured optimal temperature sensor placement under the full range of expected operating conditions to ensure an accurate characterization of the volume-averaged indoor air temperature, as well as of the spatial variability in the temperature field. The prediction of thermal performance matches well to the experiments with discrepancies lower than 0.38 °C for all the approaches, and the final widths of the 95% confidence interval are reduced to less than 0.18 °C, indicating promising predictive capabilities for buoyancy-driven natural ventilation at all stages of designs.
ISBN: 9798835548217Subjects--Topical Terms:
3391367
Heat transfer.
A Predictive Simulation Framework for Buoyancy-Driven Natural Ventilation in Office Buildings.
LDR
:02984nmm a2200361 4500
001
2349953
005
20221010063706.5
008
241004s2022 ||||||||||||||||| ||eng d
020
$a
9798835548217
035
$a
(MiAaPQ)AAI29176550
035
$a
(MiAaPQ)STANFORDbq301fy1404
035
$a
AAI29176550
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Chen, Chen.
$3
1267258
245
1 0
$a
A Predictive Simulation Framework for Buoyancy-Driven Natural Ventilation in Office Buildings.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2022
300
$a
152 p.
500
$a
Source: Dissertations Abstracts International, Volume: 84-01, Section: B.
500
$a
Advisor: Gorle, Catherine;Fischer, Martin;Kitanidis, Peter.
502
$a
Thesis (Ph.D.)--Stanford University, 2022.
506
$a
This item must not be sold to any third party vendors.
520
$a
Natural ventilation and cooling can significantly reduce building energy consumption, but inherent variability in boundary and operating conditions makes optimal and robust design of natural ventilation a challenging task. The goal of this study is to enable robust design and operation of natural ventilation systems by developing an efficient simulation framework that can predict the building's thermal response under buoyancy-driven natural ventilation. A simplified building thermal model that solves for the time-evolution of the volume-averaged indoor air temperature with uncertain quantification (UQ) can provide an intuition of the likely effects of design choices under a variety of operating conditions in the early building design stage. Subsequently, computational fluid dynamics (CFD) simulations can be employed to fine-tune the building design at the design development stage, and the CFD results can be used to reduce the uncertainty in the building thermal model coefficients that determine the flow and heat transfer rates. The predictive capability of the resulting multi-fidelity framework was validated with a carefully designed full-scale experiment performed in an operational atrium building. A CFD-based experimental design ensured optimal temperature sensor placement under the full range of expected operating conditions to ensure an accurate characterization of the volume-averaged indoor air temperature, as well as of the spatial variability in the temperature field. The prediction of thermal performance matches well to the experiments with discrepancies lower than 0.38 °C for all the approaches, and the final widths of the 95% confidence interval are reduced to less than 0.18 °C, indicating promising predictive capabilities for buoyancy-driven natural ventilation at all stages of designs.
590
$a
School code: 0212.
650
4
$a
Heat transfer.
$3
3391367
650
4
$a
Propagation.
$3
3680519
650
4
$a
Cooling.
$3
1457878
650
4
$a
Reynolds number.
$3
3681436
650
4
$a
Boundary conditions.
$3
3560411
650
4
$a
Buildings.
$3
861672
650
4
$a
Energy consumption.
$3
631630
650
4
$a
Temperature.
$3
711968
650
4
$a
Ventilation.
$3
776587
650
4
$a
Sensors.
$3
3549539
650
4
$a
Energy.
$3
876794
650
4
$a
Fluid mechanics.
$3
528155
650
4
$a
Mathematics.
$3
515831
650
4
$a
Mechanics.
$3
525881
650
4
$a
Physics.
$3
516296
650
4
$a
Thermodynamics.
$3
517304
690
$a
0791
690
$a
0204
690
$a
0405
690
$a
0346
690
$a
0605
690
$a
0348
710
2
$a
Stanford University.
$3
754827
773
0
$t
Dissertations Abstracts International
$g
84-01B.
790
$a
0212
791
$a
Ph.D.
792
$a
2022
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29176550
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9472391
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入
(1)帳號:一般為「身分證號」;外籍生或交換生則為「學號」。 (2)密碼:預設為帳號末四碼。
帳號
.
密碼
.
請在此電腦上記得個人資料
取消
忘記密碼? (請注意!您必須已在系統登記E-mail信箱方能使用。)