語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
到查詢結果
[ null ]
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
Efficient Management of Environmental Control Within Electrical Substations for Decarbonisation Purposes.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Efficient Management of Environmental Control Within Electrical Substations for Decarbonisation Purposes./
作者:
Collett, Mark.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2021,
面頁冊數:
163 p.
附註:
Source: Masters Abstracts International, Volume: 84-01.
Contained By:
Masters Abstracts International84-01.
標題:
Humidity. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29171236
ISBN:
9798835548699
Efficient Management of Environmental Control Within Electrical Substations for Decarbonisation Purposes.
Collett, Mark.
Efficient Management of Environmental Control Within Electrical Substations for Decarbonisation Purposes.
- Ann Arbor : ProQuest Dissertations & Theses, 2021 - 163 p.
Source: Masters Abstracts International, Volume: 84-01.
Thesis (M.Phil.)--University of Salford (United Kingdom), 2021.
This item must not be sold to any third party vendors.
Decarbonisation of building operations is identified as a key component of national decarbonisation strategies. Reducing the energy demand of buildings is to be achieved through more stringent regulation for new construction and the retrofitting of existing stock. These are applicable to both domestic and most non-domestic building types, although no such efforts have been made to decarbonise electrical substations.Electrical substations are critical infrastructure assets that house distribution equipment enabling electricity to reach customers' homes and business premises. To reduce the risk of damage to distribution equipment environmental, control is required to maintain specific levels of temperature and relative humidity. This research explores how these assets can be decarbonised whilst maintaining the required internal environmental conditions.Using a longitudinal case study method, three archetypal substations were subject to remote monitoring of energy consumption and environmental conditions, performance testing and energy modelling. This revealed that non-compliant humidity levels were occurring, as well as over-conditioning of temperature as a result of ineffective control systems. Consequently there was a significant performance gap detected between the measured and modelled energy consumption.Observing the monitoring results and the unique constraints of substations, a bespoke approach to retrofitting the substations was developed. Differing from more established retrofit hierarchies, this prioritised enhancement of control systems over the performance of building fabric. This ensured that the compliance of environmental conditions was guaranteed along with further decarbonisation benefits.Interventions were delivered across the three case study substations with benefits established through further monitoring of energy and environmental conditions. An overall decrease in energy consumption and payback periods between 2 and 18 years across the three sites were coupled with considerably improved environmental conditions in two sites. This study shows that the application of retrofit is applicable to substations and can result in substantial co-benefits for their operators. Whilst many of the interventions to decarbonise are not dissimilar to those applied to more established building types consideration is necessary to ensure maintaining the required environmental conditions is addressed.
ISBN: 9798835548699Subjects--Topical Terms:
3559498
Humidity.
Efficient Management of Environmental Control Within Electrical Substations for Decarbonisation Purposes.
LDR
:03601nmm a2200385 4500
001
2349009
005
20220920134644.5
008
241004s2021 ||||||||||||||||| ||eng d
020
$a
9798835548699
035
$a
(MiAaPQ)AAI29171236
035
$a
(MiAaPQ)Salford62826
035
$a
AAI29171236
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Collett, Mark.
$3
3688393
245
1 0
$a
Efficient Management of Environmental Control Within Electrical Substations for Decarbonisation Purposes.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2021
300
$a
163 p.
500
$a
Source: Masters Abstracts International, Volume: 84-01.
500
$a
Advisor: Swan, W. .
502
$a
Thesis (M.Phil.)--University of Salford (United Kingdom), 2021.
506
$a
This item must not be sold to any third party vendors.
520
$a
Decarbonisation of building operations is identified as a key component of national decarbonisation strategies. Reducing the energy demand of buildings is to be achieved through more stringent regulation for new construction and the retrofitting of existing stock. These are applicable to both domestic and most non-domestic building types, although no such efforts have been made to decarbonise electrical substations.Electrical substations are critical infrastructure assets that house distribution equipment enabling electricity to reach customers' homes and business premises. To reduce the risk of damage to distribution equipment environmental, control is required to maintain specific levels of temperature and relative humidity. This research explores how these assets can be decarbonised whilst maintaining the required internal environmental conditions.Using a longitudinal case study method, three archetypal substations were subject to remote monitoring of energy consumption and environmental conditions, performance testing and energy modelling. This revealed that non-compliant humidity levels were occurring, as well as over-conditioning of temperature as a result of ineffective control systems. Consequently there was a significant performance gap detected between the measured and modelled energy consumption.Observing the monitoring results and the unique constraints of substations, a bespoke approach to retrofitting the substations was developed. Differing from more established retrofit hierarchies, this prioritised enhancement of control systems over the performance of building fabric. This ensured that the compliance of environmental conditions was guaranteed along with further decarbonisation benefits.Interventions were delivered across the three case study substations with benefits established through further monitoring of energy and environmental conditions. An overall decrease in energy consumption and payback periods between 2 and 18 years across the three sites were coupled with considerably improved environmental conditions in two sites. This study shows that the application of retrofit is applicable to substations and can result in substantial co-benefits for their operators. Whilst many of the interventions to decarbonise are not dissimilar to those applied to more established building types consideration is necessary to ensure maintaining the required environmental conditions is addressed.
590
$a
School code: 5034.
650
4
$a
Humidity.
$3
3559498
650
4
$a
Failure.
$3
3561225
650
4
$a
Regulation.
$3
3561775
650
4
$a
Cables.
$3
851074
650
4
$a
Gases.
$3
559387
650
4
$a
Fossil fuels.
$3
701525
650
4
$a
Electricity distribution.
$3
3562889
650
4
$a
Emissions.
$3
3559499
650
4
$a
Permeability.
$3
915594
650
4
$a
Carbon.
$3
604057
650
4
$a
Intervention.
$3
3435307
650
4
$a
Electric vehicles.
$3
1613392
650
4
$a
Circuits.
$3
3555093
650
4
$a
Fines & penalties.
$3
3560680
650
4
$a
Performance evaluation.
$3
3562292
650
4
$a
Ventilation.
$3
776587
650
4
$a
Building construction.
$3
2071835
650
4
$a
Natural gas.
$3
668611
650
4
$a
Corrosion.
$3
3595443
650
4
$a
Atmospheric sciences.
$3
3168354
650
4
$a
Civil engineering.
$3
860360
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Energy.
$3
876794
650
4
$a
Engineering.
$3
586835
650
4
$a
Transportation.
$3
555912
690
$a
0725
690
$a
0543
690
$a
0501
690
$a
0544
690
$a
0791
690
$a
0537
690
$a
0338
690
$a
0709
710
2
$a
University of Salford (United Kingdom).
$3
3556058
773
0
$t
Masters Abstracts International
$g
84-01.
790
$a
5034
791
$a
M.Phil.
792
$a
2021
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=29171236
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9471447
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入
(1)帳號:一般為「身分證號」;外籍生或交換生則為「學號」。 (2)密碼:預設為帳號末四碼。
帳號
.
密碼
.
請在此電腦上記得個人資料
取消
忘記密碼? (請注意!您必須已在系統登記E-mail信箱方能使用。)