語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
到查詢結果
[ null ]
切換:
標籤
|
MARC模式
|
ISBD
Application of Liquid Chromatography...
~
Oldfield, Lucy Sian.
FindBook
Google Book
Amazon
博客來
Application of Liquid Chromatography -- Tandem Mass Spectrometry Techniques to Forensic, Environmental and Clinical Analyses.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Application of Liquid Chromatography -- Tandem Mass Spectrometry Techniques to Forensic, Environmental and Clinical Analyses./
作者:
Oldfield, Lucy Sian.
面頁冊數:
211 p.
附註:
Source: Dissertation Abstracts International, Volume: 74-11(E), Section: B.
Contained By:
Dissertation Abstracts International74-11B(E).
標題:
Chemistry, Analytical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3571620
ISBN:
9781303253737
Application of Liquid Chromatography -- Tandem Mass Spectrometry Techniques to Forensic, Environmental and Clinical Analyses.
Oldfield, Lucy Sian.
Application of Liquid Chromatography -- Tandem Mass Spectrometry Techniques to Forensic, Environmental and Clinical Analyses.
- 211 p.
Source: Dissertation Abstracts International, Volume: 74-11(E), Section: B.
Thesis (Ph.D.)--West Virginia University, 2013.
Liquid chromatography -- tandem mass spectrometry (LC-MS/MS) is a powerful technique offering superior selectivity, sensitivity and flexibility for a diverse range of applications. This document describes the application of LC-MS/MS to analytical problems in environmental, clinical and forensic fields.
ISBN: 9781303253737Subjects--Topical Terms:
586156
Chemistry, Analytical.
Application of Liquid Chromatography -- Tandem Mass Spectrometry Techniques to Forensic, Environmental and Clinical Analyses.
LDR
:03548nam a2200313 4500
001
1960459
005
20140616133318.5
008
150210s2013 ||||||||||||||||| ||eng d
020
$a
9781303253737
035
$a
(MiAaPQ)AAI3571620
035
$a
AAI3571620
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Oldfield, Lucy Sian.
$3
2096126
245
1 0
$a
Application of Liquid Chromatography -- Tandem Mass Spectrometry Techniques to Forensic, Environmental and Clinical Analyses.
300
$a
211 p.
500
$a
Source: Dissertation Abstracts International, Volume: 74-11(E), Section: B.
500
$a
Adviser: Suzanne Bell.
502
$a
Thesis (Ph.D.)--West Virginia University, 2013.
520
$a
Liquid chromatography -- tandem mass spectrometry (LC-MS/MS) is a powerful technique offering superior selectivity, sensitivity and flexibility for a diverse range of applications. This document describes the application of LC-MS/MS to analytical problems in environmental, clinical and forensic fields.
520
$a
LC-UV and LC-MS/MS methods were implemented and compared for the analysis of nitroaromatics, nitramines and nitrate esters in soil. Analysis of soils collected at detonation sites showed the presence and concentration of contaminants to be a function of parameters such as: time since detonation, type of charge employed, nature of detonation and size of charge used. Multi-increment (MI) sampling strategies recommended by the Environmental Protection Agency (EPA) were found to be impractical for wilderness environments. A structured grid strategy (SGS) is described which would allow representative sampling in complex terrain and enable the distinction between areas of high and low contamination, to more appropriately evaluate remediation needs.
520
$a
A new method was developed for the analysis of trace levels of buprenorphine, fentanyl and their metabolites in mice from low (<100 muL) plasma volumes. The method was fully validated, allowing an evaluation of current validation recommendations. The study highlighted the importance of using ion ratios as part of routine quantification, not just in method development. Another observation found that where suppression of internal standard signals resulted in reproducibility outside of standard limits (>20% RSD), if the signal was stable and within the linear range, the ratio of the analyte and internal standard signals was consistent and proportional to the concentration of analyte. This could impact current acceptance criteria for internal standard peak area reproducibility. A new hydrophilic interaction liquid chromatography (HILIC)-MS/MS method for the determination of cocaine and fentanyl, capable of indicating the smoked route of administration is described. The method was found to be highly selective and sensitive especially for basic and highly polar acidic species. Challenges facing traditional reverse phase (RP) LC separation of the highly hydrophilic compounds ecgonine, anhydroecgonine methyl ester and anhydroecgonine are eliminated in hydrophobic interaction (HI) mode through the incorporation of multiple retention mechanisms. The method could be easily adapted to the separation of other acidic, basic or highly polar drug compounds where RP separation has previously not been possible.
590
$a
School code: 0256.
650
4
$a
Chemistry, Analytical.
$3
586156
650
4
$a
Chemistry, Biochemistry.
$3
1017722
650
4
$a
Chemistry, General.
$3
1021807
690
$a
0486
690
$a
0487
690
$a
0485
710
2
$a
West Virginia University.
$b
Chemistry.
$3
2096127
773
0
$t
Dissertation Abstracts International
$g
74-11B(E).
790
$a
0256
791
$a
Ph.D.
792
$a
2013
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3571620
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9255287
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入
(1)帳號:一般為「身分證號」;外籍生或交換生則為「學號」。 (2)密碼:預設為帳號末四碼。
帳號
.
密碼
.
請在此電腦上記得個人資料
取消
忘記密碼? (請注意!您必須已在系統登記E-mail信箱方能使用。)